WEBVTT

00:00.000 --> 00:30.000 position:50% align:top line:0%
*This machine-generated transcript may have errors. If remediation or a manually-generated transcript is needed, please contact NLM Support at https://support.nlm.nih.gov.*

01:24.740 --> 01:27.610
This videotape demonstrates a series of basic

01:27.610 --> 01:30.350
techniques for ocular examination and management.

01:31.140 --> 01:34.090
The techniques have been taken from the following series of

01:34.090 --> 01:36.600
self instructional slide tape units.

01:53.340 --> 01:56.000
Since this videotape is intended to supplement the

01:56.000 --> 01:57.090
slide tape units.

01:57.540 --> 01:59.550
We recommend that you study them first,

01:59.940 --> 02:02.230
then view the videotape to refine your

02:02.230 --> 02:05.140
techniques or to answer questions about a particular

02:05.140 --> 02:05.760
technique.

02:06.840 --> 02:09.470
The videotape is meant primarily to demonstrate

02:09.470 --> 02:12.050
performance the slide tape units

02:12.330 --> 02:15.080
present examples of normal and abnormal patients

02:15.430 --> 02:18.170
and go into more detail about indications

02:18.510 --> 02:21.360
background knowledge and conditions for referral.

02:22.320 --> 02:24.980
The techniques presented our confrontation

02:24.980 --> 02:26.700
visual field testing,

02:36.230 --> 02:37.830
corneal examination,

02:40.750 --> 02:42.450
examination of the pupil,

02:48.680 --> 02:50.560
checking the anterior chamber,

02:50.560 --> 02:51.480
depth

02:54.460 --> 02:56.870
motility,

03:03.610 --> 03:05.150
basic screening

03:12.720 --> 03:14.400
installation of eye drops,
25
00:03:19.260 --> aN:aN:000NaN

03:19.260 --> 03:23.600
version,
27
00:03:25.320 --> aN:aN:000NaN

03:25.320 --> 03:30.650
patching

03:33.450 --> 03:35.980
superficial foreign body

03:35.980 --> 03:37.960
removal,
31
00:03:38.440 --> aN:aN:000NaN

03:38.440 --> 03:44.050
irrigation

03:47.170 --> 03:49.110
and ocular massager.

04:19.040 --> 04:21.410
When a patient complains of blind spots,

04:21.680 --> 04:24.140
bumping into things or other symptoms

04:24.140 --> 04:26.360
suggestive of a visual field defect.

04:26.740 --> 04:29.240
A confrontation visual field test should be

04:29.240 --> 04:29.950
performed.

04:30.740 --> 04:33.600
It is also an important part of a complete neurologic

04:33.600 --> 04:34.390
examination

04:35.940 --> 04:36.820
confrontation.

04:36.820 --> 04:39.720
Visual field testing can only rule out gross

04:39.720 --> 04:41.160
visual field defects.

04:41.840 --> 04:43.910
Each eye is tested separately.

04:45.430 --> 04:48.290
The visual field is divided into quadrants with the

04:48.290 --> 04:50.160
center at the point of fixation.

04:50.940 --> 04:53.530
First each of the quadrants is tested

04:53.530 --> 04:54.180
separately

05:01.940 --> 05:03.850
to detect more subtle defects.

05:04.190 --> 05:06.480
The left and right quadrants are tested

05:06.480 --> 05:07.550
simultaneously.

05:24.540 --> 05:27.150
Finally the nasal and temporal

05:27.150 --> 05:30.120
halves of the visual field are compared for

05:30.120 --> 05:31.360
their relative clarity

05:35.420 --> 05:36.480
in this procedure,

05:36.680 --> 05:39.560
the patient's visual field is compared with the examiners,

05:40.300 --> 05:43.160
The patient and examiners should be seated facing each other

05:43.310 --> 05:44.760
about one m apart.

05:45.740 --> 05:48.710
The patient should cover one eye and the examiner

05:48.710 --> 05:51.610
should close his own opposite I the

05:51.610 --> 05:54.470
patient should maintain fixation on the examiners

05:54.470 --> 05:57.300
open eyes in a plane

05:57.310 --> 05:59.560
midway between patient and examiner,

06:00.000 --> 06:02.830
the examiner presents his closed hands in

06:02.830 --> 06:05.550
each of the upper quadrants of his own visual field,

06:05.940 --> 06:08.910
so that he can clearly see one hand in each of his

06:08.910 --> 06:10.230
own upper quadrants.

06:10.910 --> 06:13.360
To test the upper nasal and temporal quadrants.

06:13.840 --> 06:16.570
The examiner should display 12 or

06:16.570 --> 06:18.610
five fingers on one hand,

06:18.910 --> 06:21.800
then on the other hand ask the patient how many

06:21.800 --> 06:24.680
fingers are seen randomly alternate

06:24.680 --> 06:25.320
hands.

06:25.940 --> 06:26.450
Two,

06:27.040 --> 06:27.550
one,

06:28.140 --> 06:28.560
two,

06:29.320 --> 06:29.820
two.

06:29.830 --> 06:30.590
Next 1.

06:30.990 --> 06:33.210
The examiner shows fingers of both hands

06:33.210 --> 06:36.100
simultaneously and ask the patient how many

06:36.100 --> 06:37.890
total fingers are shown?

06:38.540 --> 06:38.960
Four,

06:39.740 --> 06:40.250
two,

06:40.840 --> 06:41.460
four.

06:42.230 --> 06:44.480
This so called double simultaneous

06:44.480 --> 06:47.230
presentation may identify a subtle field

06:47.230 --> 06:49.690
defect that wasn't evident when testing the

06:49.690 --> 06:50.960
individual quadrants.

06:51.940 --> 06:54.510
Similarly the lower temporal and nasal

06:54.510 --> 06:57.460
quadrants are tested singly one,

06:58.140 --> 07:00.320
one and simultaneously

07:01.740 --> 07:02.250
two.

07:03.240 --> 07:06.190
Be sure that the patient maintains fixation on your open

07:06.190 --> 07:08.850
eye and keeps the other I completely covered.

07:10.020 --> 07:12.960
You should be able to count your own fingers at all times.

07:14.030 --> 07:16.680
Any difficulty in counting fingers suggests a

07:16.680 --> 07:18.050
visual field defect.

07:18.440 --> 07:19.170
Finally,

07:19.540 --> 07:22.530
with the patients I still covered the examiner

07:22.530 --> 07:24.600
presents the palms of both hands,

07:24.870 --> 07:27.830
left and right of center and the patient is asked

07:27.830 --> 07:30.520
if both hands are equally clear both hands

07:30.520 --> 07:31.270
equally clear

07:32.840 --> 07:35.830
blueness of any part of one hand compared to the

07:35.830 --> 07:37.550
other suggests the defect.

07:39.340 --> 07:40.750
Next the opposite.

07:40.750 --> 07:41.560
I is tested.

07:42.040 --> 07:44.570
Have the patient cover the other eye and repeat the

07:44.570 --> 07:45.250
procedure.

07:46.040 --> 07:48.860
First the upper quadrants are tested singly.

07:49.740 --> 07:49.950
Okay,

07:50.640 --> 07:52.460
one and

07:52.460 --> 07:55.050
simultaneously two.

07:55.440 --> 07:57.260
Then the lower quadrants are tested

07:58.440 --> 08:00.060
when two.

08:00.540 --> 08:01.860
One true,

08:02.440 --> 08:02.860
two.

08:03.640 --> 08:04.060
Two.

08:04.440 --> 08:07.350
Finally have the patient compare the palms for

08:07.350 --> 08:07.940
clarity,

08:08.640 --> 08:09.850
arms equally clear.

08:09.860 --> 08:10.350
Yes,

08:11.440 --> 08:13.990
the results of your testing should be described or

08:13.990 --> 08:14.650
sketched,

08:15.320 --> 08:17.980
since this is only a gross test by

08:17.980 --> 08:20.510
confrontation should be included in the

08:20.510 --> 08:21.450
patient's record.

08:22.340 --> 08:24.750
A defect demonstrated by the confrontation

08:24.750 --> 08:27.250
method requires referral for more

08:27.250 --> 08:29.260
precise visual field testing.

08:53.240 --> 08:55.860
There are four tests used to examine the Cornea,

08:58.440 --> 08:59.610
corneal clarity,

09:00.190 --> 09:01.680
corneal light reflection,

09:02.440 --> 09:05.060
fluorescent staining and corneal

09:05.060 --> 09:05.920
sensitivity

09:09.850 --> 09:11.320
as the window of the eye.

09:11.550 --> 09:13.690
The cornea must be perfectly clear.

09:14.710 --> 09:17.510
You should be able to see the irish details clearly

09:17.800 --> 09:19.860
as your pen light illuminates the eye

09:24.540 --> 09:27.250
haziness of irish details may indicate that the

09:27.250 --> 09:29.250
cornea is not entirely clear.

09:30.570 --> 09:32.480
The cornea should not only be clear,

09:33.040 --> 09:35.760
but its surface must also be perfectly smooth.

09:36.720 --> 09:39.470
This is most easily checked by examining the

09:39.470 --> 09:40.850
corneal light reflection.

09:42.540 --> 09:44.790
A good light source should be large,

09:44.930 --> 09:47.160
such as a fluorescent fixture or a window.

09:48.240 --> 09:50.910
A normal corneal surface reflects the light source

09:50.910 --> 09:53.740
clearly and sharply mirror like as

09:53.740 --> 09:55.380
demonstrated with this mirror

09:58.360 --> 09:59.930
and on an actual cornea,

09:59.970 --> 10:00.930
as seen here,

10:02.140 --> 10:05.130
any distortion of the reflected image suggests an

10:05.130 --> 10:07.280
irregularity of the corneal surface.

10:08.440 --> 10:11.430
A window or a fluorescent fixture is a good

10:11.430 --> 10:13.820
light source because any distortion of a large

10:13.820 --> 10:16.570
rectangular image is detected much more

10:16.570 --> 10:19.320
easily than distortion of a small source,

10:19.460 --> 10:20.260
such as your pen.

10:20.260 --> 10:23.050
Light with the patient

10:23.050 --> 10:24.810
seated opposite the light source

10:25.820 --> 10:27.450
tilt the patient's head is needed

10:28.640 --> 10:31.260
so that the reflection is clearly visible on the

10:31.260 --> 10:32.260
patient's cornea.

10:34.320 --> 10:36.890
Then have the patient's eyes follow your finger

10:37.010 --> 10:39.660
so that the reflection moves systematically

10:39.810 --> 10:42.360
over all parts of the cornea in

10:42.360 --> 10:43.150
succession

10:45.840 --> 10:48.260
by having the patient follow your finger up,

10:48.940 --> 10:49.620
down,

10:50.090 --> 10:51.690
left and right.

10:52.240 --> 10:55.120
The entire cornea can be systematically scanned for

10:55.120 --> 10:56.160
irregularities.

10:59.440 --> 11:01.800
Common causes of an irregular surface are

11:01.800 --> 11:02.560
abrasion,

11:03.040 --> 11:05.720
foreign body corneal ulcer or

11:05.720 --> 11:06.750
corneal scar.

11:09.040 --> 11:11.850
If a defect in the corneal surface is suspected

11:12.120 --> 11:14.260
from the history or from your examination,

11:14.840 --> 11:17.260
fluorescent staining should be performed.

11:19.910 --> 11:22.670
Floor scene will stain any area of the cornea

11:22.910 --> 11:24.970
where the epithelium has been disturbed.

11:26.010 --> 11:28.920
It is used to confirm suspected interruptions of the

11:28.920 --> 11:31.490
corneal epithelium and to detect subtle

11:31.490 --> 11:34.100
defects which might not be found in any other

11:34.100 --> 11:34.550
way.

11:35.910 --> 11:38.260
You will need some sterile floor seen strips

11:38.820 --> 11:41.560
in a squeeze bottle of sterile irrigating solution,

11:43.840 --> 11:45.460
remove a floor seen strip,

11:45.740 --> 11:47.550
taking care not to contaminate it.

11:48.940 --> 11:51.670
Place a drop of sterile irrigating solution on the

11:51.670 --> 11:52.060
tip,

11:57.240 --> 11:59.880
Retract the eyelids gently and instruct the

11:59.880 --> 12:01.860
patient to look down or up

12:04.240 --> 12:05.730
briefly touched the floor seen.

12:05.730 --> 12:07.310
Strip to the con Gentiva,

12:07.680 --> 12:09.460
above or below the cornea.

12:10.340 --> 12:13.040
Do not touch the cornea as an abrasion could

12:13.040 --> 12:13.550
result,

12:15.340 --> 12:18.270
have the patient blink a few times so that the flow racine

12:18.270 --> 12:19.750
is spread over the cornea

12:21.440 --> 12:24.350
flush out any excess floor scene with some

12:24.350 --> 12:26.280
drops of sterile irrigating solution,

12:31.340 --> 12:34.020
Check the cornea for any areas where the dye is

12:34.020 --> 12:34.730
retained.

12:39.230 --> 12:41.660
Any green staining that adheres to the cornea

12:42.250 --> 12:44.580
denotes an area of damaged epithelium

12:48.840 --> 12:51.270
Corneal sensitivity testing is indicated

12:51.740 --> 12:54.430
when you wish to test the integrity of the 5th

12:54.430 --> 12:57.270
cranial nerve or to determine

12:57.610 --> 12:59.950
if a herpes simplex infection has

12:59.950 --> 13:02.360
compromised the superficial nerve endings.

13:03.740 --> 13:04.670
If indicated,

13:04.920 --> 13:07.830
corneal sensitivity should be checked after fluorescent

13:07.830 --> 13:10.660
staining since the sensitivity test may

13:10.660 --> 13:13.270
cause an ia tra genetically positive fluorescent

13:13.270 --> 13:13.850
stain.

13:15.540 --> 13:18.270
The examiner first teases out some strands from a

13:18.270 --> 13:19.250
cotton swab.

13:20.240 --> 13:22.910
Then the patients should be instructed to look to the side

13:23.150 --> 13:24.050
opposite the eye.

13:24.050 --> 13:24.900
Being tested,

13:28.540 --> 13:30.540
the examiner retracts the eyelids

13:31.540 --> 13:33.540
and brings the swab in laterally.

13:33.800 --> 13:36.610
To avoid a visually evoked blink response.

13:37.740 --> 13:40.570
Then the peripheral cornea is lightly touched with the teased

13:40.570 --> 13:41.490
out strands.

13:43.040 --> 13:44.880
When normal sensation is present,

13:45.260 --> 13:48.170
a light touch applied to the cornea evokes a blink

13:48.170 --> 13:50.360
reflex and slight discomfort.

13:55.330 --> 13:57.140
Repeat the test on the other eye.

13:57.150 --> 13:59.860
Using a new cotton swab to avoid any

13:59.860 --> 14:01.900
possibility of cross contamination.

14:04.440 --> 14:07.340
You should ask the patient if the touch felt the same in each

14:07.340 --> 14:07.780
eye.

14:13.940 --> 14:16.760
Reviewing the four tests used to examine the Cornea

14:17.320 --> 14:19.760
first make sure the cornea is perfectly

14:19.760 --> 14:22.500
clear and that the irish details are easily

14:22.500 --> 14:23.060
seen.

14:25.540 --> 14:27.490
Then check the surface of the cornea.

14:27.770 --> 14:28.600
Using a large,

14:28.600 --> 14:30.060
rectangular light source

14:33.040 --> 14:35.890
fluorescent staining will confirm suspected

14:35.890 --> 14:38.010
interruptions of the corneal epithelium.

14:40.340 --> 14:40.990
Finally,

14:41.280 --> 14:44.270
to check the integrity of the fifth cranial nerve or

14:44.270 --> 14:47.160
to determine if a herpes simplex infection has

14:47.160 --> 14:49.360
compromised the superficial nerve endings,

14:49.740 --> 14:51.690
corneal sensitivity is tested.

15:20.640 --> 15:22.050
When examining the pupils,

15:22.100 --> 15:23.610
you should check them for shape,

15:23.710 --> 15:25.670
size and reaction to light

15:26.730 --> 15:29.250
pupils should be tested in a semi dark room,

15:29.540 --> 15:32.410
since inequality has become more obvious when the pupils are

15:32.410 --> 15:35.390
wide instruct the patient to look

15:35.400 --> 15:38.330
at an object at least 10 ft away to prevent

15:38.330 --> 15:41.090
the constriction of the pupil due to the near reflex,

15:42.240 --> 15:44.900
the pupil should be round and in the center of the

15:44.900 --> 15:45.390
iris.

15:46.840 --> 15:49.620
The pupil should be approximately equal in diameter.

15:50.440 --> 15:53.120
A difference in diameter of greater than one millimeter

15:53.440 --> 15:55.750
may indicate a significant abnormality.

15:59.980 --> 16:02.890
To check the pupils reaction to light first

16:02.900 --> 16:04.430
illicit the direct pupil.

16:04.430 --> 16:05.290
Every reaction

16:08.700 --> 16:11.420
Shine your penlight into one I the

16:11.420 --> 16:14.010
pupil of this I should constrict quickly and

16:14.010 --> 16:14.630
smoothly

16:18.340 --> 16:21.160
Shining a light into one pupil should also

16:21.160 --> 16:24.150
bring about symmetrical constriction of the opposite pupil.

16:24.990 --> 16:26.710
This is the consensual pupil.

16:26.710 --> 16:27.550
Every reaction

16:31.130 --> 16:33.040
as you shine your hand light into one,

16:33.040 --> 16:35.860
I observe the pupil of the other eye for

16:35.860 --> 16:37.440
consensual constriction.

16:42.140 --> 16:45.100
Similarly observe the direct and consensual

16:45.100 --> 16:48.030
pupil very reactions with the light shining in the

16:48.030 --> 16:48.650
other eye,

16:50.840 --> 16:53.520
analyzing the direct and consensual reactions

16:53.770 --> 16:56.770
will help you determine if there is a defect of the different

16:56.780 --> 16:58.070
sensory pathways.

16:59.040 --> 17:01.870
Notice that the pupils are unequal here and the

17:01.870 --> 17:04.840
left pupil of this patient does not react to a light

17:04.840 --> 17:06.640
stimulus shone directly into it,

17:07.130 --> 17:08.770
nor does it react consensually.

17:15.520 --> 17:18.270
The swinging flashlight test is a sensitive screening

17:18.270 --> 17:21.230
method for detecting defects in the different

17:21.230 --> 17:22.440
sensory pathways.

17:26.040 --> 17:28.780
The test is based on the fact that an eye with a

17:28.780 --> 17:31.180
defect of the different sensory pathway

17:31.630 --> 17:34.000
effectively receives a weaker stimulus

17:34.560 --> 17:37.370
and thus has a weaker pupil eri response than a

17:37.370 --> 17:38.070
normal I.

17:40.240 --> 17:42.550
When the hand light shines into the normal I.

17:43.040 --> 17:45.530
A normal direct and consensual

17:45.530 --> 17:46.960
response is seen

17:48.840 --> 17:51.760
when the flashlight swings quickly to the abnormal

17:51.760 --> 17:52.180
I.

17:52.630 --> 17:55.540
The direct reaction is less than the previous consensual

17:55.540 --> 17:57.620
reaction and thus a

17:57.620 --> 18:00.060
paradoxical dilatation occurs

18:01.060 --> 18:03.570
since the stimulus to this I is not adequately

18:03.570 --> 18:04.860
transmitted centrally.

18:05.520 --> 18:08.350
The direct and consensual reactions are decreased

18:08.740 --> 18:10.060
or may even be absent.

18:11.040 --> 18:13.850
When the light is quickly swung back to the normal I

18:14.290 --> 18:16.260
breast constriction is seen again.

18:17.740 --> 18:20.460
This patient has an abnormality of the optic nerve.

18:21.320 --> 18:23.600
Watch as the swinging flashlight test is

18:23.600 --> 18:24.400
demonstrated,

18:25.280 --> 18:28.270
swing your light back and forth quickly several times

18:28.600 --> 18:31.500
to make sure that the response is consistent and

18:31.500 --> 18:33.350
that you did not miss a subtle difference.

18:34.240 --> 18:37.190
It is crucial that the light be swung very quickly between

18:37.190 --> 18:39.770
the two eyes in order to avoid the normal

18:39.770 --> 18:42.310
dilation from the relatively low level of

18:42.310 --> 18:43.610
ambient illumination.

18:47.220 --> 18:49.830
The paradoxical debilitation is called a

18:49.840 --> 18:51.380
Marcus Gunn pupil

19:15.440 --> 19:17.960
while you are using your hand light to check the pupil,

19:18.440 --> 19:21.060
you can also use it to check the depth of the anterior

19:21.060 --> 19:21.620
chamber.

19:22.240 --> 19:24.980
This is an important screening test for possible narrow

19:24.980 --> 19:25.960
angle glaucoma.

19:27.740 --> 19:30.120
The anterior chamber is the space between the

19:30.120 --> 19:31.590
cornea and the iris.

19:32.490 --> 19:35.100
In a shallow chamber the iris bulges

19:35.100 --> 19:35.710
forward,

19:35.980 --> 19:38.780
interrupting a light beam shining across the iris

19:39.240 --> 19:42.240
and causing a shadow to fall over the part of the iris

19:42.290 --> 19:43.560
away from the penlight.

19:44.780 --> 19:46.060
In a normal chamber,

19:46.540 --> 19:49.280
the beam will shine across the entire iris

19:54.650 --> 19:55.950
to check the chamber depth,

19:56.500 --> 19:58.780
shine your pen light from the side of the eye.

19:59.820 --> 20:00.500
Normally,

20:00.770 --> 20:02.960
the light illuminates the entire iris.

20:02.970 --> 20:03.960
As shown here

20:07.750 --> 20:08.980
in a narrow chamber,

20:09.320 --> 20:12.000
a shadow falls on the nasal side of the iris.

20:12.240 --> 20:15.060
As shown here in patients with a

20:15.060 --> 20:17.220
shallow chamber dilating,

20:17.220 --> 20:19.570
the pupil may cause a chamber angle block,

20:19.800 --> 20:22.060
triggering an attack of acute glaucoma.

20:22.840 --> 20:25.600
These patients should not be dilated and should be

20:25.600 --> 20:28.130
referred to an ophthalmologist for appropriate

20:28.140 --> 20:28.670
care.

20:44.840 --> 20:45.000
Yeah.

20:52.380 --> 20:55.070
In the evaluation of extra ocular muscle function

20:55.290 --> 20:58.170
there are four aspects range of motion

20:58.740 --> 21:00.100
smoothness of motion,

21:00.620 --> 21:01.460
stability,

21:02.060 --> 21:03.440
an alignment of the eyes

21:05.140 --> 21:07.160
to test the patients range of motion.

21:08.040 --> 21:10.610
Have the patient follow your finger into the

21:10.610 --> 21:12.860
six cardinal positions of gays.

21:13.940 --> 21:16.900
You should note whether there is any limitation in the ability

21:16.900 --> 21:19.800
of one or both eyes to move into the various

21:19.800 --> 21:20.530
positions

21:23.860 --> 21:26.640
when in doubt about whether one eye is limited in movement,

21:27.040 --> 21:29.880
compare its range of movement to that of the other

21:29.880 --> 21:30.270
eye.

21:31.840 --> 21:33.940
A limitation of movement of one eye.

21:34.160 --> 21:37.100
As demonstrated here may indicate either

21:37.100 --> 21:39.230
a mechanical constraint or a

21:39.230 --> 21:40.110
paralysis.

21:48.640 --> 21:51.320
When both eyes cannot move to a given direction

21:51.720 --> 21:54.390
it indicates a gaze palsy of super

21:54.390 --> 21:55.480
nuclear origin.

21:56.330 --> 21:59.170
In all cases the patient should be referred for

21:59.170 --> 22:00.870
ophthalmological evaluation

22:03.110 --> 22:05.130
while the patient is following your finger.

22:05.640 --> 22:07.860
Also note the smoothness of motion

22:08.760 --> 22:10.900
and the ability to hold the eyes still.

22:11.240 --> 22:13.460
As the patient fixates on your finger,

22:15.020 --> 22:17.520
inability to hold the eyes still is known as

22:17.520 --> 22:18.380
nystagmus.

22:19.580 --> 22:22.320
Nystagmus may remain the same in all positions of

22:22.320 --> 22:25.100
gays or maybe more pronounced in some

22:25.100 --> 22:27.420
positions and absent in others.

22:28.230 --> 22:30.770
Such differences should be noted if present,

22:33.530 --> 22:36.330
notice the jerk nystagmus evidenced by this

22:36.330 --> 22:36.950
patient

22:47.040 --> 22:48.770
and the pendulum nystagmus

22:49.440 --> 22:51.170
demonstrated by this patient.

22:52.440 --> 22:55.370
Any patient with nystagmus who has not been evaluated

22:55.370 --> 22:57.670
previously should also be referred.

23:01.740 --> 23:02.360
Finally,

23:02.920 --> 23:04.710
check the alignment of the eyes.

23:05.740 --> 23:08.610
Patient complaints of diplo pia or double

23:08.610 --> 23:11.390
vision often originate from defects in the alignment

23:11.390 --> 23:12.760
mechanism of the eyes.

23:14.420 --> 23:17.300
You can determine if the eyes are straight or binocular

23:17.300 --> 23:19.970
early aligned by noting the relative

23:19.970 --> 23:22.170
position of the corneal light reflections

23:23.480 --> 23:25.900
as the patient fixates on a light source.

23:26.270 --> 23:29.190
The corneal reflection should be positioned over the center

23:29.190 --> 23:30.380
of the two pupils.

23:31.720 --> 23:32.650
In this patient.

23:33.010 --> 23:35.690
The corneal reflection of the left eye is not in the

23:35.690 --> 23:38.680
center of the pupil If

23:38.680 --> 23:40.800
you suspect deviation of one I.

23:41.180 --> 23:43.270
A cover test should be performed.

23:44.240 --> 23:46.550
Have the patient stare at a distant object

23:47.640 --> 23:50.500
with your hand Cover one eye and

23:50.500 --> 23:52.520
watch for any movement of the other eye

23:53.440 --> 23:55.360
repeat this with the other eye.

23:56.740 --> 23:59.410
Since both eyes are aligned on the same target

23:59.940 --> 24:02.510
covering either I should normally not

24:02.510 --> 24:03.960
result in any movement.

24:05.230 --> 24:07.800
If one eye is not aligned with the fixation

24:07.800 --> 24:08.350
target,

24:08.940 --> 24:11.850
then covering the I will cause the nonaligned

24:11.850 --> 24:14.550
I to move to take up fixation.

24:15.620 --> 24:18.260
You see in this patient that covering the normal I

24:18.500 --> 24:19.650
resulted in movement.

24:19.950 --> 24:22.730
Since only the normal I was already fixating on the

24:22.730 --> 24:23.250
target.

24:25.000 --> 24:27.650
Testing for alignment of the eyes is particularly

24:27.650 --> 24:29.300
important in young patients,

24:29.800 --> 24:32.540
since an untreated deviation may lead to lifelong

24:32.540 --> 24:33.360
amblyopia,

24:53.740 --> 24:54.360
mm hmm.

24:57.380 --> 25:00.250
Several ophthalmological examining techniques have been

25:00.250 --> 25:02.540
demonstrated confrontation,

25:02.540 --> 25:05.540
visual field testing anterior chamber,

25:05.540 --> 25:07.910
depth check examination of the

25:07.910 --> 25:09.600
pupil corneal,

25:09.600 --> 25:09.840
light,

25:09.840 --> 25:10.790
reflection,

25:10.800 --> 25:12.560
corneal sensitivity,

25:13.140 --> 25:15.330
corneal clarity and

25:15.330 --> 25:16.500
motility.

25:16.540 --> 25:19.310
Some of these techniques need only be performed as

25:19.310 --> 25:20.060
indicated.

25:20.540 --> 25:23.540
Others are important to use on every patient

25:23.550 --> 25:25.250
as part of your routine physical

25:25.250 --> 25:26.590
examination.

25:26.600 --> 25:29.410
Such a basic screening takes little time

25:29.420 --> 25:32.420
and will now be demonstrated in patients

25:32.420 --> 25:34.030
without ocular complaints.

25:34.040 --> 25:36.800
This screening should detect most latent eye

25:36.800 --> 25:38.030
problems.

25:42.730 --> 25:45.150
There are four basic ocular history screening

25:45.150 --> 25:45.910
questions.

25:46.640 --> 25:48.940
Ask the patient whether her vision has ever been

25:48.940 --> 25:51.940
decreased and also whether it is the

25:51.940 --> 25:53.440
same in both eyes.

25:54.600 --> 25:56.670
Then ask whether the eyes have been red,

25:56.870 --> 25:58.950
painful or otherwise bothersome.

25:59.940 --> 26:00.630
Finally,

26:01.040 --> 26:03.920
ask whether a doctor or anyone else has ever

26:03.920 --> 26:06.560
told the patient that there was anything abnormal or

26:06.560 --> 26:08.240
unusual about the eyes.

26:09.340 --> 26:12.080
After taking the ocular history begin the

26:12.080 --> 26:12.960
examination,

26:14.240 --> 26:15.050
test your eyes.

26:15.050 --> 26:15.170
Now,

26:15.940 --> 26:18.060
would you cover the left eye

26:18.840 --> 26:21.670
palm of your hand and look down towards

26:21.670 --> 26:24.010
that chart over there and read

26:24.420 --> 26:26.550
the line just under the green line.

26:27.340 --> 26:27.740
Okay.

26:27.970 --> 26:29.060
You see those letters.

26:29.740 --> 26:30.340
T.

26:30.390 --> 26:33.360
P E O L F

26:33.740 --> 26:34.670
DZ.

26:35.040 --> 26:35.360
Good.

26:35.740 --> 26:37.060
Now cover your other eye.

26:37.940 --> 26:38.270
Okay.

26:40.440 --> 26:41.190
Okay.

26:41.940 --> 26:44.800
T P E O L

26:44.810 --> 26:45.340
F.

26:45.350 --> 26:45.740
D.

26:45.740 --> 26:46.170
Z.

26:47.940 --> 26:48.560
Okay.

26:49.120 --> 26:52.090
Now I'm going to look at your eyes to

26:52.090 --> 26:52.770
look over there,

27:03.640 --> 27:04.170
look up.

27:08.940 --> 27:09.170
Okay,

27:33.040 --> 27:33.970
fine.

27:34.290 --> 27:35.420
Now look at my finger.

27:41.840 --> 27:44.640
This patient's eyes fixate and moves smoothly

27:44.650 --> 27:47.220
over the full range of motion and they are well

27:47.220 --> 27:47.860
aligned.

27:49.340 --> 27:52.060
The next step is op Tomasz Capi

27:56.640 --> 27:57.430
1 2nd.

27:57.620 --> 27:58.780
I'll turn off the lights.

28:03.440 --> 28:05.330
I'm going to look inside your eye now.

28:05.340 --> 28:08.150
I'd like you to look right at that door knob across the way.

28:08.370 --> 28:10.460
Try not to look directly at my life.

28:33.740 --> 28:34.060
Mhm.

28:34.440 --> 28:35.860
I'm going to look in your other eye.

28:35.860 --> 28:37.050
Look over my other shoulder.

28:38.240 --> 28:38.770
Same place

29:02.440 --> 29:03.670
your eyes look fine.

29:06.740 --> 29:09.520
The last thing I'm gonna do is check the pressure inside your

29:09.520 --> 29:09.890
eye.

29:11.640 --> 29:12.860
Would you lie down please?

29:13.340 --> 29:13.550
Thank you.

29:18.340 --> 29:20.740
Has anybody in your family had glaucoma?

29:20.960 --> 29:21.730
Not that I know of.

29:22.000 --> 29:24.200
Have you ever had the pressure in your eyes checked?

29:25.940 --> 29:28.550
I'm going to put some numbing drops in your eyes right now.

29:28.940 --> 29:29.170
Mhm.

29:29.940 --> 29:31.460
So you won't feel the instrument.

29:32.260 --> 29:32.980
Look up for me.

29:32.990 --> 29:35.990
Please Try not to rub or press on your eyes for

29:35.990 --> 29:37.300
the next 15 minutes.

29:37.840 --> 29:39.270
Otherwise you might scratch them.

29:40.740 --> 29:41.060
Mhm.

29:42.960 --> 29:44.270
Here's a tissue for you.

29:48.640 --> 29:51.620
I want you to take your thumb and hold it up over your head over

29:51.620 --> 29:52.060
here.

29:52.940 --> 29:53.500
That's good.

29:53.510 --> 29:55.360
Just keep looking right at the thumb.

29:55.840 --> 29:57.910
Try to pay no attention to this instrument.

29:57.910 --> 29:59.620
Just keep looking right at your car.

29:59.890 --> 30:00.850
That's perfect.

30:01.800 --> 30:03.270
Keep looking at your thumb.

30:08.040 --> 30:09.360
Put your thumb down now.

30:09.740 --> 30:11.960
The pressure in your eyes are perfectly normal.

30:13.630 --> 30:16.570
This patient received a basic but comprehensive

30:16.570 --> 30:19.070
ocular examination in a very short

30:19.080 --> 30:19.660
time.

30:20.430 --> 30:23.140
The technical details of 10 on the tree and up to Mosca

30:23.140 --> 30:23.450
P.

30:23.610 --> 30:26.160
Are covered in the other self instructional units.

30:28.910 --> 30:31.170
If the patient had any ocular complaints

30:31.640 --> 30:34.320
or if you had found any abnormalities in this

30:34.320 --> 30:37.090
screening examination you might have spent more

30:37.090 --> 30:39.820
time exploring the specific findings as

30:39.820 --> 30:41.740
outlined in the tape slide units

31:07.890 --> 31:09.320
to instill eye drops.

31:09.530 --> 31:12.160
The patient should be seated or lying supine.

31:13.320 --> 31:15.780
The patient's head should be tilted back slightly

31:17.340 --> 31:19.950
With a tissue in one hand retract the

31:19.950 --> 31:22.890
patient's upper lid with the

31:22.890 --> 31:25.600
fourth or fifth finger of the other hand which is

31:25.600 --> 31:26.990
also holding the dropper.

31:27.330 --> 31:28.600
Retract the lower lid,

31:30.140 --> 31:31.850
instruct the patient to look up

31:33.040 --> 31:35.850
and instill a drop into the inferior con gente

31:35.850 --> 31:36.550
Vilsack.

31:37.640 --> 31:40.160
Do not place the drop directly onto the cornea

31:42.180 --> 31:44.230
to avoid contact with the lashes.

31:44.740 --> 31:47.510
Hold the bottle high enough so that the normal blink

31:47.510 --> 31:49.890
reflex does not bring the lashes into

31:49.890 --> 31:52.060
contact with the tip of the dropper.

31:54.040 --> 31:56.870
Blot any excess fluid from around the patients.

31:56.870 --> 31:57.270
II
