Pennsylvania Patient Safety Advisory Medication Errors with the Dosing of Insulin: Problems across the Continuum ABSTRACT morbidity in critically ill surgical patients.4 The study Controlling blood sugars with insulin is essential in the design employed a continuous infusion of insulin to management of hyperglycemia in both diabetic and maintain blood glucose between 80 mg/dL and 110 nondiabetic patients. However, studies have shown mg/dL. Patients receiving intensive insulin therapy that the use of insulin has been associated with more were found to be less likely to require prolonged medication errors than any other type or class of drug. mechanical ventilation and intensive care. Also, From January 2008 to June 6, 2009, Pennsylvania rigorous insulin treatment reduced the number of healthcare facilities submitted 2,685 event reports to deaths from multiple-organ failure with sepsis, regard- the Authority that mentioned medication errors involv- less of whether there was a history of diabetes or ing the use of insulin products. The most common hyperglycemia. types of medication error associated with insulin were drug omission (24.7%) followed by wrong-drug errors The NICE-SUGAR study evaluated whether there was (13.9%). More than 52% of the reported events led a difference in mortality between subjects randomly assigned to either intensive glucose control (target to situations in which a patient may have or actually blood glucose range of 81 mg/dL to 108 mg/dL) or received the wrong dose or no dose of insulin (e.g., conventional glucose control (target of 180 mg/dL dose omissions, wrong dose/overdosage, wrong or less).5 The study showed that the odds of dying dose/underdosage, extra dose, wrong rate errors), with intensive control were 1.14 times greater than which could lead to difficulties in glycemic control. with conventional control. In addition, severe hypo- Strategies to address these problems include limiting glycemia (blood glucose level of 40 mg/dL) occurred the variety of insulin products on the organization’s in 6.8% of the intensive-control group and 0.5% in formularies, developing standardized protocols and the conventional-control group. The NICE-SUGAR a standard format for prescribing insulin, avoiding study also demonstrated that there was no significant the use of abbreviations or other shortcuts when difference between the two treatment groups in the communicating orders for insulin, and requiring an median number of days in the ICU or hospital or in independent double check of all doses before dis- the median number of days of mechanical ventilation pensing and administering intravenous insulin. or renal-replacement therapy. (Pa Patient Saf Advis 2010 Mar;7[1]:9-17.) In a meta-analysis of randomized controlled trials of tight glucose control versus usual care in critically ill Introduction adults, the authors found no significant difference in hospital mortality or new need for dialysis. Although An estimated 23.6 million Americans (nearly 8% of tight glucose control was associated with a significant the U.S. population) have diabetes mellitus. In 2007, reduction in septicemia overall, subgroup analysis sug- approximately 17.9 million people have been diagnosed gested this benefit was limited to surgical ICU patients. with the disease, and 5.7 million remain undiagnosed.1 Conversely, they found clear evidence that hypoglyce- Among adults diagnosed with type 1 or type 2 diabe- mia increased roughly fivefold, regardless of the ICU tes, 14% take insulin only, 13% take both insulin and setting, and was more common with patients receiving oral medication, 57% take oral medication only, and very, rather than moderately, tight glucose control.6 16% do not take either insulin or oral medication.2 For many years, literature has shown that the use of Glycemic control is fundamental to the management insulin has been associated with more medication of diabetes. Insulin is used to control blood sugars in errors than any other type or class of drug. Cohen et both diabetic and nondiabetic patients. For example, al. reported in 1998 that 11% of harmful medication it is used to manage hyperglycemia in intensive care errors result from insulin misadministration.7 The unit (ICU) patients, a common finding caused by U.S. Pharmacopeia MEDMARX 2008 data report insulin resistance in the liver and muscle tissue. Some showed that insulin was the leading product involved have considered insulin resistance to be an adaptive in harmful medication errors (i.e., National Coor- response, providing glucose for the brain, red blood dinating Council for Medication Error Reporting cells, and wound healing.3 and Prevention [NCC MERP] harm index8 E to I), Due to a number of conflicting published studies, representing 16.2% of all harmful medication error there has been an increased effort to determine the reports.9 In 2004, the Pennsylvania Patient Safety benefit of tightly controlled blood glucose levels, both Authority established that 25% of all medications in diabetic and nondiabetic patients. For example, in errors reported involve high-alert medications, and a large, single-center study of postoperative surgical 16.3% involved insulin products.10 This article presents patients, an initial investigation by van den Berghe analysis of events involving insulin products reported et al. suggested that controlling blood glucose levels to the Authority during an approximately 17-month by intensive insulin therapy decreased mortality and period and describes the most common types of errors Vol. 7, No. 1—March 2010 REPRINTED ARTICLE - ©2010 Pennsylvania Patient Safety Authority Page 9 Pennsylvania Patient Safety Advisory involving the use of insulin, as well as those events that During review of the wrong-drug medication errors, could contribute to uncontrolled blood sugars. analysts found that facilities did not enter the actual name of the insulin products consistently into the A Look at the Numbers reports. In fact, 70% (n = 262) of the submitted reports Pennsylvania healthcare facilities submitted 2,685 did not list a specific insulin product (e.g.,“insulin,” event reports to the Authority from January 2008 “regular insulin,” “NPH insulin,” “insulin 70/30”) or to June 6, 2009, that mentioned medication errors listed names of products that do not exist (e.g., “Huma- involving the use of insulin products. Categoriza- log 70/30,” “Humalog R,” “Humulin 75/25”). This tion by harm score, which is adapted from the NCC imprecise data collection limits individual facilities and MERP harm index,8 shows that 78.7% (n = 2,113) of the Authority from accurately determining the most the events reached the patient (harm index = C to I) common pairs of insulin products involved in wrong- and 1.8% (n = 49) of the events resulted in patient drug errors. In addition, many of these reports did not harm (harm index = E to I). The care areas most often specifically state why the error occurred or what went cited in these reports include medical/surgical units wrong that led to the patient receiving the wrong insu- (22.3%, n = 599), pharmacy (8.7%, n = 234), and lin product. Therefore, it was not possible to determine telemetry (7.1%, n = 191). Roughly 53% (n = 1,434) the most common types of wrong-drug errors that of the events involved elderly patients (ages 65 years occurred (e.g., wrong drugs that may have been written and older), while 1.7% (n = 46) involved pediatric by prescribers, selected during order entry, mislabeled patients (ages younger than 17 years). in the pharmacy, wrongly pulled from stock). Analysts The predominant medication error event types associ- were able to determine the following: ated with insulin (see Table) were drug omission (24.7%, ■ Seventy-five (20%) reports of wrong-drug insulin n = 662) followed by wrong drug (13.9%, n = 374) and errors specifically mention that the breakdown wrong dose/overdosage (13%, n = 348). More than occurred when retrieving the medication, for exam- 52% (n = 1,409) of the reported events led to situations ple, from stock or an automated dispensing cabinet in which a patient may have or actually did receive the (ADC). Specifically, 28 reports (37.3% of stock wrong dose or no dose of insulin (e.g., dose omissions, errors) mentioned the use of overrides to obtain wrong dose/overdosage, wrong dose/underdosage the insulin product from an ADC. [5.1%, n = 137], extra dose [8.5%, n = 227], wrong rate [1.3%, n = 36]), which could lead to fluctuations in gly- ■ Sixty-nine (18.4%) of wrong-drug insulin errors cemic control. involved mix-ups between a rapid acting insulin (e.g., Novolog, Humalog) and regular insulin Wrong-Drug Errors Associated with Insulin (e.g., Novolin R, Humulin R, regular insulin). Products ■ Sixty-five (17.4%) reports of the wrong-drug events There are numerous case reports in the literature that specifically identified that the error occurred dur- discuss the issue of wrong-drug medication errors ing the prescribing node. Most of these reports with insulin products due to similarities in the brand involved the clarification of nonspecific (e.g., a and generic names, as well as similarity in labeling specific insulin product was not indicated) orders, and packaging.11-14 The Authority has noted mix-ups such as the following: between names occurring in Pennsylvania facilities The physician wrote an order for “Novolin 18 units (e.g., Humalog® and Humalog 75/25, Humalog and bid.” The order was not clarified when taken off, Humulin® R, Humalog 75/25 and Humulin 70/30, and regular insulin was given for two doses. When Novolog® and Humalog, Novolog 70/30 and the physician came in the following day, the order Novolin® 70/30).15 was clarified, and he ordered Novolin N insulin. The patient was given two doses of Novolin R. Intravenous (IV) administration of insulin has Table. Predominant Medication Error some advantages over subcutaneous administration, Event Types Associated with the Use of namely (1) more rapid onset of effect in controlling Insulin (N = 2,057, 76.6%), January 2008 hyperglycemia, (2) more overall ability to achieve gly- to June 6, 2009 cemic control, and (3) improved nonglycemic patient outcomes.16 During IV insulin infusion to control % OF TOTAL hyperglycemic crises, hypoglycemia, if it occurs, is REPORTS short-lived; however, repeated administration of EVENT TYPE NUMBER (N = 2,685)* subcutaneous insulin may result in “stacking” the Dose omission 662 24.7% insulin’s effect, causing protracted hypoglycemia.16 Wrong drug 374 13.9% Wrong dose/overdosage 348 13% The stability of an IV insulin infusion is 24 hours and requires the production of insulin infusions by Other (specify) 309 11.5% pharmacy when ordered. Unless this infusion is dis- Extra dose 227 8.5% tinguished with highlighting or a prominent sticker, Wrong dose/underdosage 137 5.1% an insulin infusion will resemble other pharmacy- * Sum of percentages exceeds 76.6% due to rounding. prepared infusions. Of the wrong-drug errors involving insulin reported to the Authority, infusion bags Page 10 REPRINTED ARTICLE - ©2010 Pennsylvania Patient Safety Authority Vol. 7, No. 1—March 2010 Pennsylvania Patient Safety Advisory containing insulin were mentioned in 9.4% (n = 35) controlling a patient’s blood glucose. For example, of the cases. Nearly 88.6% (n = 31) of these reports correction doses, sometimes referred to as “coverage” reached the patient, and 11.4% (n = 4) resulted in or erroneously as “sliding scales,” are used to adjust patient harm. Patients accidentally received insulin glucose levels around mealtimes. Organizations often instead of a noninsulin-containing infusion (e.g., have multiple algorithms for corrections doses, such antibiotics) in 60% (n = 21) of these wrong-drug, that a facility may have “low dose,” “medium dose,” infusion-related reports. Examples are as follows: and “high dose” algorithms that require the nursing An IV insulin bag was hung when replacing the staff to obtain and document each patient’s blood patient’s Versed® (midazolam) bag. Two bags of insu- glucose reading, determine the patient’s ordered algo- lin were then hanging, one at rate of 8 (Versed rate) rithm, and then select the proper dose based on the and one at 5 (insulin rate). A [mid-afternoon] accu- blood glucose reading. check showed that the [blood glucose] level decreased The predominant theme mentioned in reports of to 36. D50 was administered as per protocol, and the wrong-dose events involves the dosing of insulin based insulin drip was turned off. The wrong-bag error was on a range of blood glucose values with a correspond- found at [the next] change of shift. ing coverage dose, determined by a patient’s blood A patient was ordered IV Lasix® (furosemide), as glucose reading. Of the wrong-dose errors submitted well as IV insulin. The nurse meant to hang the IV to the Authority (n = 712), 26% (n = 185) mention Lasix but [before midnight] hung a bag of IV insulin coverage or sliding scales. (Many events reported to instead. The patient already had an insulin infusion the Authority used the phrase “sliding scale” in the running. Approximately [four hours later], the patient narratives to denote the method used to determine was noted to be hypoglycemic. Both IV drips were the dose of insulin to administer to patients. While turned off at that time, and the patient was given this term may be used in place of “correction dose” or 50 ml of 50% dextrose. The RN [registered nurse] “coverage,” it should be noted that sliding-scale insu- still believed that one of the IV drips was Lasix at lin regimens used alone are ineffective and potentially this time. Four hours later, the oncoming RN was harmful. When using subcutaneous insulin injec- checking and verifying the patient’s IV drips and tion therapy, scheduled or standing insulin regimens discovered the error. The patient required several more should be the standard of care.18-21) As mentioned doses of 50% dextrose throughout the morning to previously, this recommended method of maintaining correct episodes of hypoglycemia. tight control of a patient’s blood sugar, regardless if the patient is diabetic or not, adds complexity to the Wrong-Dose Errors with Insulin medication-use process for all healthcare practitioners. Analysis of events that resulted in patients receiving One problem often seen with coverage orders is the a type of wrong dose (e.g., wrong dose/overdosage, clarity of handwritten orders from physicians, a par- wrong dose/underdosage, extra dose) reveals a variety ticular problem when an organization does not have a of breakdowns that occurred in the medication-use standardized protocol or order form to order insulin, process, including problems with insulin coverage including the type of coverage (e.g., low, high). Add- orders, ambiguous orders written by prescribers, ing to the complexity of these orders are the multiple transcription and order-entry errors, the obtainment values often used for multiple ranges of blood sugars. and/or use of the incorrect blood glucose value of Problems have also occurred when shortcuts are taken the patient, and the ways in which information about when writing these types of orders for insulin. For insulin products is displayed on pharmacy labels and example, orders have been written stating doses of medication administration records. insulin as “6+1” or “6+2” instead of writing out “7” About 10.4% (n = 36) of the wrong dose/overdosage or “8” (see Figure 1). events reported to the Authority involved a tenfold Once these complex orders have been written, prob- overdose of insulin. lems have occurred when transcribing the orders to Insulin Coverage Orders medication administration records (MARs) or enter- The Diabetes Control and Complications Trial, a ing them into computerized order-entry systems. prospective, randomized controlled trial of intensive Errors also have occurred when selecting the blood versus standard glycemic control involving inpatients glucose range, dose, or algorithm from a pharmacy with relatively recently diagnosed type 1 diabetes, label, a handwritten MAR, or a computer-generated showed that improved glycemic control is associated with significantly decreased rates of microvascular Figure 1. Example of Ambiguous Insulin (retinopathy and nephropathy) as well as neuropathic “Coverage” Order complications.17 This led to the recommendation that type 1 diabetes be treated by using multiple insulin injections (three to four injections per day of basal and prandial insulin) as well as by matching the dose of prandial insulin to carbohydrate intake, pre-meal blood glucose, and anticipated activity. However, the use of multiple-dose injections of Reprinted with permission from the Institute for Safe Medication Practices, insulin throughout the day has added complexity to Horsham, Pennsylvania. Vol. 7, No. 1—March 2010 REPRINTED ARTICLE - ©2010 Pennsylvania Patient Safety Authority Page 11 Pennsylvania Patient Safety Advisory MAR (see Figure 2). Pennsylvania facilities are expe- Figure 2. Example of “Coverage” Order riencing these types of errors as evidenced by these Complicated Directions on a MAR events reported to the Authority: A patient was ordered insulin on sliding scale level 2, but the order was transcribed incorrectly on the MAR as sliding scale level 1. The patient received two doses at level 1 coverage instead of level 2. The error was found during the 24-hour MAR check. A patient was changed from high-dose sliding scale coverage to moderate dose. Order was transcribed onto medication sheet as bedtime coverage, but Reprinted with permission from the Institute for Safe Medication Practices, original order was for no bedtime coverage. Patient Horsham, Pennsylvania. received four units of insulin. Ambiguous Orders Written by Prescribers transferred, and the nurse administered the evening There has been much written about problems with dose of Lantus 70 units as ordered, with appropriate handwritten orders for insulin, including the use double check. The patient later questioned dose, stat- of dangerous abbreviations or dose expressions and ing “I take 7 units.” other shortcuts when communicating orders. How A patient was ordered “20 units Lantus q 24hr.” the use of the letter “U” to abbreviate “unit” has The pharmacist misread the order and transcribed contributed to medication errors has been discussed the order onto the MAR as “Lantus 200 units.” The for several decades.22 Errors that have occurred when nurse administered 200 units Lantus [that evening], using “U” for unit have resulted when the “U” resem- and [two hours later], the patient’s blood sugar was bles the number “0” or “4.” Reports to the Authority reported as 54. The nurse increased tube feedings, reveal similar examples of wrong doses due to the use and subsequent accuchecks were read as “error.” of shortcuts when writing orders for insulin. The physician transcribed an incorrect insulin dose Intern wrote order for 8 U of insulin, which was tran- from the transfer orders. Physician wrote 70 units of scribed as 80 units of insulin. insulin instead of 7 units of insulin. The physician Order written by the doctor as “ss insulin 10u tid misinterpreted the order due to the fact that the u (for Novolog.” The order should have been clarified but units) was very close to the 7 on the transfer orders. was not and should have been written according to Transcribing and Order-Entry Errors abbreviation policy. The order was transcribed as Among the wrong-dose insulin errors, 13.8% (n = 98) “Novolog 10 Units TID,” but the order was intended of the events involved breakdowns that occurred when to be “Sliding Scale Low TID.” transcribing orders, such as when entering orders into The physician wrote “ss” for sliding scale, and the an MAR or a computerized order-entry system. Exam- staff transcribed the order as “55 units.” The error ples reported to the Authority include the following: was caught prior to administration. A patient was ordered “human regular insulin 150 Order on chart is for Humalog 4 units, but it had units subcutaneously qam prn,” with the reason stat- said 5 units, and the 5 was crossed off, and the 4 ing that the patient was on the medication at home. was placed in front of the crossed-off 5. Therefore the The order was entered as a nonformulary drug request. order appeared to say 45 units and was placed in by I questioned the order and discovered that the patient pharmacy . . . and verified by the nurse as 45 units. has a sliding scale regimen [as follows:] if blood sugar The chart was reviewed due to the very high dose of is 150 to 200: give 2 units; blood sugar 201 to 250: Novolog to be given, and it was found that the 5 was 4 units; blood sugar 251 to 300: 6 units; blood sugar crossed off. The pharmacy was called, and they cor- 301 to 350: 8 units; blood sugar 351 to 400: 10 rected the dose. units; and blood sugar 401 to 500: 12 units. The first Although writing out the complete word “units” is blood sugar parameter was incorrectly entered by the the recommended alternative to using the abbrevia- [physician] as the insulin dose. tion “U,” be aware that tenfold overdoses may still A physician wrote an order for a patient to receive occur when writing the word “unit(s),” particularly four units of regular insulin if the patient’s early when there is inadequate white space between the morning blood sugar was equal to or greater than dose number and the word (see Figure 3). Examples 250. Blood sugar was checked, and it was 179, so reported to the Authority include the following: patient should not have received any insulin. The A patient was admitted to the ED [emergency depart- original order was transcribed incorrectly in that clerk ment] after [the patient’s] morning insulin had been wrote four units of Humalog 75/25 instead of regu- administered. The ED completed medication reconcili- lar insulin. Not only did patient receive insulin when ation documentation, including “insulin 7units.” The he shouldn’t, but he received the wrong insulin. The resident referred to the written medication reconcili- transcription on the medication Kardex had not been ation document, perceiving the insulin dose to read cosigned by two nursing staff as is our policy. “70units.” Resident ordered Lantus 70 units bid, Medication verification sheet documented a wrong and the pharmacy verified the order. The patient was dose of 70/30 insulin as per patient’s spouse bringing Page 12 REPRINTED ARTICLE - ©2010 Pennsylvania Patient Safety Authority Vol. 7, No. 1—March 2010 Pennsylvania Patient Safety Advisory Figure 3. Order Written for 8 Units of Lantus Insulin Displays on Insulin Products on Pharmacy Labels Misread as 80 Units and MARs Most pharmacy-generated labels, both in acute care and outpatient settings, display the name and strength (i.e., concentration) of the drug on the same line. For Humalog, many labels read “Humalog 100 units/mL” on the first line, with the intended dose for the pa- Reprinted with permission from the Institute for Safe Medication Practices, tient appearing on the line below the drug name and Horsham, Pennsylvania. concentration (see Figures 4 and 5). Similarly, phar- macy-provided, computer-generated MARs and other in recent hospital discharge instructions sheet of medi- forms of drug information display dosage strength or cations as proof. The patient was ordered 10 units of concentration information the same way as the label. 70/30 insulin, but the order was transcribed as Display of drug and dosing information in this way 40 units. has led practitioners to misinterpret the drug’s Obtaining and/or Using the Correct Blood Glucose strength or concentration (100 units/mL) as the pa- tient’s dose. Although this issue was only apparent Value of the Patient in 14 events reported to the Authority, it is of great In addition to the 30 events reported as “Monitor- concern because of the potentially large difference ing errors/Clinical lab values,” 12.9% (n = 92) of the between the intended dose and the administered dose. wrong-dose events involved breakdowns with obtain- ing and/or communicating patients’ blood glucose Patient was on Lantus insulin at the nursing home. values. Specific problems reported to the Authority When physician was reviewing the medication orders included reporting an incorrect value, confusing the from the nursing home, the Lantus order read “Lantus patient’s weight for his or her blood glucose level, and 100 units/ml vial inject 15 units sub q at bedtime.” communicating the wrong patient’s value, as well as The physician misinterpreted this order to mean simply documenting the wrong result. Both licensed Lantus 100 units sub q at bedtime and ordered it as professionals and support staff have been involved in such. The patient’s blood sugar was 85 [that evening], these breakdowns. so this dose was not given, and it was subsequently decreased to 80 units. The patient did receive the The patient’s blood sugar was written on the board 80 units the next day, and the blood sugar dropped as 148. The patient was given two units of regular to 52 two days later. The Lantus dose was decreased insulin [that evening]. When the history in the glu- again to 40 units on the following day and was cometer was checked, the patient’s actual reading administered at bedtime. [The follow morning,] the was 450. An additional 10 units of regular insulin patient arrested, and patient’s blood sugar was 12. was given at [one and a half hours later]. The printed medication list from a previous facility The nurse asked the nursing assistant for the indicated “Lantus 100 units/ml 15 units once a day patient’s Accucheck results. The nurse was told that subcutaneously at 8pm.” The nurse reconciling the the blood glucose was 377. The patient was covered patient’s medications misread the order as 100 units. with 10 units of Humalog per sliding scale guidelines. The medications were reviewed with the physician When the nursing assistant wrote the Accuchecks on and obtained telephone order for “Lantus 100 units the bulletin board, the blood glucose of 97 was writ- SQ at hs.” The nurse administering medications gave ten for that patient. as ordered. The nurse used the wrong number for the coverage, The patient’s medication reconciliation form indicates using the patient’s weight of 341 pounds, when the that the patient takes 100 units of Lantus in addition BG was 81. The nurse’s aide gave her the wrong to Januvia® and metformin. When I saw these medi- number. cations ordered for [the evening dose], I questioned the A nurse extern came out of patient’s room at the time patient on the amount of Lantus he takes at home. accuchecks are performed. The nurse extern stated He said “15 cc.” I explained that insulin comes in “211,” and RN repeated “211, right?” The nurse units. I brought him a syringe and asked how high he extern was referring to the patient’s daily weight, fills it, and he pointed to 15 units. I asked how much which is supposed to be performed at 7:30 a.m. The he had last night, and he said the nurse brought in a nurse covered the patient with four units of regular large syringe full of insulin. The nurse gave 100 units insulin when five minutes later nurse extern informed of Lantus last night according to the computer screen. the RN that the patient’s blood glucose level was 130. The patient only takes 14 units at dinnertime. In a similar example reported by the Institute for Safe Medication Practices (ISMP), a nurse picked up a piece U-500 Insulin of scrap paper that listed several patients with a num- Most insulin products are supplied from the manufac- ber next to each name.23 All of the numbers were well turer in a 100 unit/mL concentration. The insulin is above 200. Assuming the numbers were blood glucose then administered using an insulin syringe specially results, she administered insulin to each patient using designed for use with this concentration of insulin. a sliding scale protocol. Afterward, she realized that When a patient needs a dose of 40 units, a caregiver the numbers were actually patient room numbers. draws the insulin to the designated 40-unit marking Vol. 7, No. 1—March 2010 REPRINTED ARTICLE - ©2010 Pennsylvania Patient Safety Authority Page 13 Pennsylvania Patient Safety Advisory on the insulin syringe. However, there is a more con- (another 50 mL D50W given). The patient returned centrated form of insulin that comes as a 500 unit/mL to normal blood glucose of 85 at 9:30 a.m. Wednesday concentration. after D50W administration and eating breakfast. The use of U-500 insulin has been increasing due U-500 insulin was prescribed as units (from a U-100 to factors including an escalating obesity epidemic, syringe) instead of volume. The patient subsequently increasing insulin resistance, growing use of insu- received 1/5 of his insulin dose, and his blood sugars lin pumps, and rising usage of high doses for tight became excessively high. glucose control.24 However, there are no insulin syringes designed to measure doses of U-500 insulin; therefore, A case reported by ISMP involves an endocrinologist healthcare practitioners are forced to prescribe, dis- who wrote an order for 25 units of U-500 insulin to pense, and administer U-500 insulin using insulin be given in the morning.25 Nurses correctly calculated syringes designed for 100 units/mL insulin or other that the volume needed for a 25-unit dose of the syringes marked in mL. For example, a patient using 500 units/mL concentration was only 0.05 mL. A U-500 insulin with a U-100 syringe might state his call was made to the physician to ask about changing dose as “40 units” because he is reading 40 units on to U-100 insulin for more accurate measurement. the U-100 syringe he used to administer the insulin. The doctor said that he actually wanted his patient However, he is actually administering 200 units of to receive 125 units. He simply thought it would be insulin because of the higher concentration. This easier for the nurses if he prescribed 25 units know- increases the risk that a fivefold dosing error will ing that the “25 units” marking on a U-100 insulin occur when the patient communicates his dose to syringe scale would actually measure 125 units when a healthcare practitioner. The Authority’s database U-500 insulin was used. In another case, a physician includes the following examples: changed a patient’s insulin to U-500 and prescribed 5 units at noon and 8 units at dinnertime. As in the A patient was admitted on routine regular insulin, and first case, the doctor meant for the nurses to use a sliding scale was ordered at admission. [On Monday, U-100 syringe when preparing and administering the] physician ordered that the patient may use home the U-500 insulin. Thus, he intended the patient to insulin. The pharmacist modified the insulin orders receive 25 units at noon and 40 units at supper.25 with additional signature of the patient’s own medi- cations. The order in the computer system used 100 Problems also arise with the vials on nursing units. units/mL, and the patient’s actual med was Humulin One case involved a vial of U-500 insulin that was R U-500 (a concentration of 500 units/mL). The regi- left in a nursing unit refrigerator after the patient for men ordered was Humulin R 85 units before lunch, whom it was prescribed went home.26 While looking 70 units before breakfast, 95 units before supper, and for regular insulin in the refrigerator, a nurse saw the 35 units [at bedtime]. Doses [Monday evening through familiar brand name, Humulin R (regular insulin) but Tuesday bedtime] may have been given using ordered did not notice the U-500 concentration. She drew volume in computer (based on 100 unit/mL) using the the prescribed dose into a U-100 insulin syringe and patient’s own 500 unit/mL concentration; therefore, administered it. Luckily, another nurse saw the vial possibly five times the desired amount was given. The that was used and noticed that the U-500 insulin was glucose reading [6 a.m. Wednesday morning] was 39 given in error—a fivefold overdose. (25 mL D50W given), and repeat readings at 8:30 a.m. and 8:35 a.m. were 23 and 26 respectively Risk Reduction Strategies Organizations should strive to identify system-based Figure 4. Section of an MAR Listing Insulin causes of errors with the use of both insulin vials and Name with Concentration of 100 Units/mL on insulin pen devices and implement effective types of the Same Line error reduction strategies. Error reduction strategies such as constraints and standardization, which are more powerful because they focus on systems, will be more effective than education alone, which relies on individual performance and will likely be ineffective Reprinted with permission from the Institute for Safe Medication when used alone. Practices, Horsham, Pennsylvania. Constraints Figure 5. Outpatient/Community Pharmacy Label Organizations should use strategies that lessen the Listing Insulin and Concentration of 100 Units/mL chance of harm with the use of insulin. For example, on the Same Line an organization could attempt to reduce or limit the variety of insulin products on its formulary.27 In addition, organizations could remove patient-specific insulin vials, including U-500 insulin, from patient care areas upon patient discharge. Standardization Reprinted with permission from the Institute for Safe Medication Practices, Many strategies that could prevent harm with the Horsham, Pennsylvania. use of insulin could be addressed by simplifying and Page 14 REPRINTED ARTICLE - ©2010 Pennsylvania Patient Safety Authority Vol. 7, No. 1—March 2010 Pennsylvania Patient Safety Advisory standardizing the many processes surrounding its use. ■ Apply bold labels on atypical insulin concentrations.27 They include the following: Redundancies ■ Standardize and simplify orders for insulin. 28 For example, require an independent double check of — Develop standardized protocols and a standard all doses before dispensing and administering IV insu- format for prescribing insulin, preferably using lin. Build the double check into daily work processes preprinted order forms or electronic order sets so it can be accomplished without disruption.28 that list specific products, ingredients, and Education and Information component ratios.29 Education and information strategies include the — Include generic names for insulin products following: on protocols, computer screens, MARs, and ■ Provide staff with ongoing education about insulin labels, when possible, to reduce confusion products and methods of delivery.28 between brand names.29 ■ Prepare a chart that lists all insulin products used — Establish a standardized algorithm within the in your facility. Include generic and brand names; organization for the dosing of insulin when concentration; onset, peak, and duration of action; providing coverage with meals. acceptable routes of administration; time of admin- — Avoid the use of abbreviations or other short- istration in relationship to meals; appropriate drug cuts when communicating orders for insulin. delivery devices; and special precautions (e.g., mea- Use the complete word “units” when express- suring the proper dose, mixing instructions, more ing doses and concentrations of insulin.28 Do frequent patient glucose monitoring). Pictures of not use the abbreviation “U.” In addition, do the boxes in which insulin is packaged also would not use “SSRI” as an abbreviation for sliding- be helpful. Post the charts in areas where insulin is scale regular insulin, because it has been prescribed, dispensed, and administered.28 misinterpreted as selective serotonin-reuptake ■ Check MARs and pharmacy labels to identify inhibitor.29 truncated information about insulin products and — Use a single, standard concentration for adult take steps to clarify important drug information as IV insulin infusions. If a nonstandard insulin needed.31 Work with vendors to modify the appear- concentration is needed, list the concentration ance of MAR/eMAR and pharmacy labeling entries and the patient’s dose in units and volume.29 so that the wording is congruent with how medica- tions will be administered (e.g., 10 units) rather — Establish a plan for treating hypoglycemia for than how they are supplied (e.g., 100 units/mL)28 each patient. Track all episodes of hypoglyce- Monitoring of Adverse Events mia in the hospital.30 Historically, measurement efforts have focused on ■ Safely store and dispense insulin.28 practitioner reporting of medication errors, which, — Do not keep insulin vials on top of medication at best, uncovers just a fraction of the errors, most of carts or counters or under pharmacy com- them harmless.32 Consider measures other than practi- pounding hoods, as insulin could be confused tioner reporting of medication errors to evaluate your with heparin, which also is measured in units. organization’s safe use of insulin, including the follow- Put all insulin back in the appropriate storage ing examples: area immediately after use.28 ■ Assess core processes associated with insulin use by — Separate insulin products from one another in using process measures. refrigerators (i.e., avoid storing multiple types ■ Obtain outcome measures by evaluating patient of insulin together in a single bin). Consider records using a list of triggers is the most effective using visual clues, such as affixing a photo to means of collecting data on adverse drug events. the bin of the vial that should be stored there, (Visit the Authority’s Web site at http://patientsafety to help ensure that the correct vial is returned authority.org/EducationalTools/PatientSafetyTools/ to the correct bin. Pages/home.aspx to view or download a sample tool Differentiate that can be used to identify and monitor actual or Employ strategies to distinguish or make insulin prod- potential problems with the use of insulin.) ucts different in appearance, such as the following: U-500 Insulin Strategies ■ Have pharmacy prepare and dispense prefilled Strategies unique to the use of U-500 insulin include syringes for once daily doses of long-acting insulin the following: (e.g., insulin glargine).28 ■ Ensure consistent use of a tuberculin syringe with ■ Emphasize the word “mixture” or “mix,” along with U-500 insulin, with total doses expressed in terms of the name of the insulin product mixtures, for drug both units and volume (e.g., 200 units [0.4 mL]).33 selection screens.29 ■ Establish a practice to have pharmacy draw up and ■ Use tall man lettering in order-entry screens, medi- dispense the ordered dose of U-500 insulin with a cation administration records (MAR) and pharmacy second individual (e.g., nurse, technician) perform- labeling (e.g. NovoLOG, NovoLIN, HumaLOG, ing an independent check of the vial, syringe, and HumaLIN). contents.25 Vol. 7, No. 1—March 2010 REPRINTED ARTICLE - ©2010 Pennsylvania Patient Safety Authority Page 15 Pennsylvania Patient Safety Advisory Beside Blood Glucose Monitoring 11. Institute for Safe Medication Practices. Proliferation of Organizations must determine the safest way to receive, insulin combination products increases opportunity for document, communicate, and verify glucose meter errors. ISMP Med Saf Alert 2002 Nov 27;7(24):2. readings. Sample strategies include the following: 12. Institute for Safe Medication Practices. Complexity of ■ Nurses need to know patient’s blood glucose level insulin therapy has risen sharply in the past decade—part I. ISMP Med Saf Alert 2002 April 17;7(8):1. before administering insulin. A flow sheet for recording each dose of medication and correspond- 13. Institute for Safe Medication Practices. Safety Brief. ISMP ing lab values allows nurses to review previously Med Saf Alert 2000 May 3;5(9):1. administered doses and track the patient’s overall 14. Institute for Safe Medication Practices. Getting the right response to therapy.34 insulin is becoming a real crapshoot. ISMP Med Saf Alert ■ Require nursing assistants to write the patient’s 2004 Jul 15;9(14):2. blood sugar on the MAR so the nurse can give the 15. Complexity of insulin therapy. PA PSRS Patient Saf correct amount of insulin.23 Advis [online] 2005 Jun [cited 2009 Nov 11]. Available from Internet: http://patientsafetyauthority.org/ ■ Discourage verbal communication of blood ADVISORIES/AdvisoryLibrary/2005/jun2(2)/ glucose results. Documents/30.pdf. Notes 16. Clement S, Braithwaite SS, Magee MF, et al. Manage- 1. National Diabetes Information Clearinghouse. National ment of diabetes and hyperglycemia in hospitals. Diabetes Diabetes Statistics, 2007. Prevalence of Diagnosed and Care 2004 Feb;27(2):553-91. Undiagnosed Diabetes in the United States, All Ages, 17. The effect of intensive treatment of diabetes on the devel- 2007 [online]. 2008 Jun [cite 2009 Aug 27]. Available opment and progression of long-term complications in from Internet: http://diabetes.niddk.nih.gov/DM/ insulin-dependent diabetes mellitus. The Diabetes PUBS/statistics/#allages. Control and Complications Trial Research Group. 2. National Diabetes Information Clearninghouse. National N Engl J Med 1993 Sep;329(14):977–86. Diabetes Statistics, 2007. Treating Diabetes [online]. 2008 18. Queale WS, Seidler AJ, Brancati FL. Glycemic control Jun [cited 2009 Aug 27]. Available from Internet: http:// and sliding scale insulin use in medical inpatients diabetes.niddk.nih.gov/DM/PUBS/statistics/#treating. with diabetes mellitus. Arch Intern Med 1997 Mar 3. Institute for Healthcare Improvement. Implement Effec- 10;157(5):545-52. tive Glucose Control [online]. [cited 2009 Oct 29]. 19. Gearhart JG, Duncan JL 3rd, Replogle WH, et al. Efficacy Available from Internet: http://www.ihi.org/IHI/ of sliding-scale insulin therapy: a comparison with pro- Topics/CriticalCare/IntensiveCare/Changes/ spective regimens. Fam Pract Res J 1994 Dec;14(4):313-22. ImplementEffectiveGlucoseControl.htm. 20. Baldwin D, Villanueva G, McNutt R, et al. Eliminating 4. van den Berghe G, Wouters P, Weekers F, et al. Intensive inpatient sliding-scale insulin: a reeducation project with insulin therapy in critically ill patients. N Engl J Med 2001 medical house staff. Diabetes Care 2005 May;28(5):1008-11. Nov 8;345(19):1359-67. 21. Magee MF, Clement S. Subcutaneous insulin therapy in 5. NICE-SUGAR Study Investigators, Finfer S, Chit- the hospital setting: issues, concerns, and implementa- tock DR, et al. Intensive versus conventional glucose tion. Endocr Pract 2004 Mar-Apr;10 Suppl 2:81-8. control in critically ill patients. N Engl J Med 2009 Mar 22. Cohen MR. Medication Error Reports. Hosp Pharm 1975 26;360(13):1283-97. Mar;10(3):120. 6. Wiener RS, Wiener DC, Larson RJ. Benefits and risks 23. Institute for Safe Medication Practices. Don’t try to “sweet of tight glucose control in critically ill adults: a meta- talk” me! ISMP Med Saf Alert 2003 Nov 27; 8(24):1. analysis. JAMA 2008 Aug 27;300(8):933-44. 24. Institute for Safe Medication Practices. Safety brief: 7. Cohen MR, Proulx SM, Crawford SY. Survey of hospital insulin concentrate U-500. ISMP Med Saf Alert 2007 Jul systems and common serious medication errors. J Healthc 26;12(15):1. Risk Manag 1998 Winter;18(1):16-27. 25. Institute for Safe Medication Practices. Insulin syringe is 8. National Coordinating Council for Medication Error not meant for U-500 insulin. ISMP Med Saf Alert 2001 Reporting and Prevention (NCC MERP). NCC MERP Oct 17;6(21):2. index for categorizing medication errors [online]. 2001. [cited 2009 Aug 27]. Available from Internet: http:// 26. Institute for Safe Medication Practices. Safety brief. ISMP www.nccmerp.org/pdf/indexColor2001-06-12.pdf. Med Saf Alert 2001 Mar 21;6(6):2. 9. U.S. Pharmacopiea. MEDMARX data report. Techni- 27. Cohen MR, Di Domizio G, Lee RE. The role of drug cal appendix 12: products most frequently involved names in medication errors. In: Cohen MR. Medication in harmful medication errors (Categories E-I), errors, 2nd ed. Washington (DC): American Pharmaceuti- CY 2006 [online]. 2008 [cited 2010 Feb 4]. Avail- cal Association; 2007. able from Internet: http://www.usp.org/pdf/EN/ 28. Institute for Safe Medication Practices. Complexity of medmarx/2008MEDMARXReport.pdf insulin therapy has risen sharply in the past decade—part 10. Focus on high-alert medications. PA PSRS Patient Saf II. ISMP Med Saf Alert 2002 May 1;7(9):1-2. Advis [online] 2004 Sep [cited 2009 Nov 11]. Available 29. Cohen MR, Smetzer JL, Tuohy MR, et al. High alert from Internet: http://patientsafetyauthority.org/ medications: safeguarding against errors. In: Cohen MR. ADVISORIES/AdvisoryLibrary/2004/Sep1(3)/ Medication errors, 2nd ed. Washington (DC): American Documents/06.pdf. Pharmaceutical Association; 2007. Page 16 REPRINTED ARTICLE - ©2010 Pennsylvania Patient Safety Authority Vol. 7, No. 1—March 2010 Pennsylvania Patient Safety Advisory ? 30. American Diabetes Association. Standards of medical care in 33. Institute for Safe Medication Practices. Extra caution diabetes—2009. Diabetes Care 2009 Jan; 32 Suppl 1:S13-61. needed with U-500 insulin. ISMP Med Saf Alert 1997 Jan 31. Institute for Safe Medication Practices. Restricted character 29;2(2):2. space and truncated drug listings are a set-up for medica- 34. Smetzer JL, Cohen MR. Preventing drug administration tion errors. ISMP Med Saf Alert 2008 Jun 5;13(11):3. errors. In: Cohen MR. Medication errors, 2nd ed. Washing- 32. Institute for Safe Medication Practices. Measuring up to ton (DC): American Pharmaceutical Association; 2007. medication safety. ISMP Med Saf Alert 2005 Mar 10; 10(5):1. ? Self-Assessment Questions The following questions about this article may be useful for internal education and assessment. You may use the following 4. All of the following strategies can be used to prevent errors with the use of insulin EXCEPT: examples or come up with your own. a. Limiting the variety of insulin products on an organiza- 1. What is the most common type of reported medication tion’s formulary error associated with the use of insulin? b. Establishing a standardized algorithm for dosing insu- a. Wrong drug lin when providing coverage with meals b. Wrong dose/overdosage c. Using multiple, patient-specific concentrations for c. Dose omission adult IV insulin infusions d. Extra dose d. Having pharmacy prepare and dispense prefilled syringes for once-daily doses of long-acting insulin e. Wrong dose/underdosage e. Requiring an independent double check of all doses of 2. Breakdowns or errors that lead to reported wrong-dose insulin before dispensing and administering IV insulin medication errors associated with insulin include all of the infusions following EXCEPT: 5. Which of the following statements about concentration a. Use of insulin coverage orders and U-500 insulin is INACCURATE? b. Ambiguous orders written by prescribers a. The use of U-500 insulin has been increasing due to c. Inaccuracies when obtaining and/or using a patient’s factors including an escalating obesity epidemic, increas- blood glucose value ing insulin resistance, growing use of insulin pumps, d. Errors when transcribing and entering orders into a and rising usage of high doses for tight glucose control. computer system b. Prescribe U-500 insulin in units based on a U-100 syringe. e. Use of a standardized protocol or order form to c. There are no insulin syringes designed to measure order insulin doses of U-500 insulin. 3. Which of the following statements about the reported d. Use tuberculin syringes when administering U-500 wrong-drugs errors associated with insulin products is insulin, with total doses expressed in terms of both INACCURATE? units and volume (e.g., 150 units [0.3 mL]). a. A majority of the submitted wrong-drug reports did e. Establish a practice to have pharmacy draw up and dis- not list a specific insulin product or listed names of pense ordered doses of U-500 insulin. products that do not exist. 6. A physician wrote an order for a patient to “decrease Lan- b. Wrong-drug insulin errors included breakdowns that tus insulin to 8 u qd,” but the order was transcribed as 80 occurred when retrieving the medication from stock or units. The medication was administered as transcribed, and an automated dispensing cabinet. the patient’s blood sugars were documented as 40 mg/dl. c. Most of the submitted reports that occurred during Predict which of the following strategies would NOT help the prescribing phase involved the clarification of non- prevent this event from reoccurring. specific orders (i.e., a specific insulin product was not a. Develop a standard format for prescribing insulin, pref- indicated). erably using preprinted order forms or electronic order d. The most common type of wrong-drug errors involving sets that list specific products, ingredients, and compo- insulin occurred when insulin vials were mislabeled in nent ratios. the pharmacy. b. Avoid the use of abbreviations or other shortcuts when e. Most of the wrong-drug errors involving infusion bags communicating orders for insulin. containing insulin reached the patient. c. Use tall man lettering in order-entry screens, medica- tion administration records, and pharmacy labeling. d. Require an independent double check of all doses before dispensing and administering IV insulin. e. None of the above. Vol. 7, No. 1—March 2010 REPRINTED ARTICLE - ©2010 Pennsylvania Patient Safety Authority Page 17 PENNSYLVANIA PATIENT SAFETY ADVISORY This article is reprinted from the Pennsylvania Patient Safety Advisory, Vol. 7, No. 1—March 2010. The Advisory is a publication of the Pennsylvania Patient Safety Authority, produced by ECRI Institute and ISMP under contract to the Authority. Copyright 2010 by the Pennsylvania Patient Safety Authority. This publication may be reprinted and distributed without restriction, provided it is printed or distributed in its entirety and without alteration. Individual articles may be reprinted in their entirety and without alteration provided the source is clearly attributed. This publication is disseminated via e-mail. To subscribe, go to https://www.papsrs.state.pa.us/ Workflow/MailingListAddition.aspx. To see other articles or issues of the Advisory, visit our Web site at http://www.patientsafetyauthority.org. Click on “Patient Safety Advisories” in the left-hand menu bar. THE PENNSYLVANIA PATIENT SAFETY AUTHORITY AND ITS CONTRACTORS The Pennsylvania Patient Safety Authority is an independent state agency created by Act 13 of 2002, the Medical Care Availability and Reduction of Error (“Mcare”) Act. Consistent with Act 13, ECRI Institute, as contractor for the Authority, is issuing this publication to advise medical facilities of immediate changes that can be instituted to reduce Serious Events and Incidents. For more information about the Pennsylvania Patient Safety Authority, see the Authority’s Web An Independent Agency of the Commonwealth of Pennsylvania site at http://www.patientsafetyauthority.org. ECRI Institute, a nonprofit organization, dedicates itself to bringing the discipline of applied scientific research in healthcare to uncover the best approaches to improving patient care. As pioneers in this science for nearly 40 years, ECRI Institute marries experience and independence with the objectivity of evidence-based research. More than 5,000 healthcare organizations worldwide rely on ECRI Institute’s expertise in patient safety improvement, risk and quality management, and healthcare processes, devices, procedures and drug technology. The Institute for Safe Medication Practices (ISMP) is an independent, nonprofit organization dedicated solely to medication error prevention and safe medication use. ISMP provides recommendations for the safe use of medications to the healthcare community including healthcare professionals, government agencies, accrediting organizations, and consumers. ISMP’s efforts are built on a nonpunitive approach and systems-based solutions.