STATE OE NEW YORK DEPARTMENT OF LABOR ALBANY OFFICE THE CAPITOL NEW YORK OFFICE 124 EAST 28th STREET BERNARD L. SHIENTAG INDUSTRIAL COMMISSIONER 1924 THE HAZARDS DUE TO THE EXHAUST FROM GASOLINE MOTORS Prepared by THE DIVISION OF INDUSTRIAL HYGIENE LELAND E. COFER, M. D., DIRECTOR STATE DEPARTMENT OF LABOR Bernard L. Shientag, Industrial Commissioner Richard J. Cullen, Deputy Commissioner Sara McPike, Secretary THE INDUSTRIAL BOARD Richard H. Curran John D. Higgins, Chairman Frances Perkins THE HAZARDS DUE TO THE EXHAUST FROM GASOLINE MOTORS By Ettore Ciampolini, M.D., PH.D., C.P.H. Medical Inspector of Factories-New York State Department of Labor-Division of Industrial Hygiene 1. Posological Properties of Carbon Monoxide. Carbon monoxide is a poisonous gas. It is the cause of one of the commonest forms of gas poisoning, both suicidal and acci- dental, and it has been recognized to be the etiological factor of the impairment of health in workers in garages (4). Carbon monoxide is an inorganic compound of carbon and oxygen. There are two direct inorganic compounds of carbon and oxygen; carbon monoxide (CO) and carbon dioxide (CO2) which must be differentiated. Carbon dioxide (C02) is not poisonous in itself. It is a product of complete oxidation of carbon and it is a normal constituent of the atmosphere. "Pure" air contains 0.03 per cent of this gas. It is an essential factor in the chemism of chlorophylie plants and in the mechanism of animal respiration (5). It is innocouous within large percentage variations. Tolerance may be obtained in atmospheres containing even 10 per cent of carbon dioxide (6). Carbon monoxide (CO), called also carbon oxide, instead is an extremely poisonous gas. Air containing 0.3 per cent of carbon monoxide is fatal, and 0.2 per cent of carbon monoxide in the air is dangerous (7), if breathed for any considerable period, depending on the time required to produce a given degree of satu- ration of the hemoglobin of the blood. Breathing in an atmos- phere containing as low an amount of carbon monoxide as 0.027 per cent, noticeable effects, as shortness of breath on exertion, may be observed (8). 2. Chemical and Physical Properties of Carbon Monoxide. The chemical composition of carbon monoxide by weight is: CO = 12 carbon, 16 oxygen. Carbon monoxide is a colorless, odorless and tasteless gas. Its specific gravity is 0.973 being slightly lighter than air. A litre of carbon monoxide weighs 1.2515 grams; a litre of dry air weighs 1.29396 grams, at the temperature of O °C and 760 mm. pressure. Carbon monoxide is practically insoluble in water. It does not oxidize spontaneously to carbon dioxide (CO2). It is a com- bustible gas burning in the air with a pale blue flame and then generating carbon dioxide (CO2). [3] 4 Carbon monoxide (CO) is a product of partial oxidation of carbon. Whenever any material containing carbon is burned without enough supply of oxygen to combine with carbon and to form carbon dioxide the result of the incomplete combustion is •carbon monoxide (CO). Aside from being present in illuminating gas where the pro- portion of CO in the various gas mixtures runs from 7.75 per cent to 38.0 per cent by volume, (9) most cities limiting the amount, the occurrence of this poisonous gas in our modern industrial age is so frequent that more weight ought to be given to this occupational hazard. 3. Mode of Poisonous Action of CO. The poisonous action of CO is due to its combination with the hemoglobin (Hb) or red coloring matter of the blood cells, forming a stable compound, carbon monoxyhemoglobin (COHb). Until the carbon monoxide is again displaced by oxygen, the combination of carbon monoxide with hemoglobin being reversible (1) the hemoglobin is deprived of its function of oxygen carrier from the lungs to the tissues of the body, producing a condition of asphyxia. The whole toxicity of carbon monoxide depends on its union with the hemoglobin (11), but as the hemoglobin attracts carbon monoxide about three hundred times as strongly as it does oxygen, absorption of CO by the hemoglobin occurs even at low concentration of carbon monoxide in the air. Professor Yandell Henderson of Yale University and his asso- ciates have worked out a carbon monoxide dissociation curve of the blood, which theoretically shows that if air containing ten parts of carbon monoxide in 10,000, or 0.1 per cent is breathed long enough to a point of equilibrium, the blood should become saturated about 66.6 per cent or sufficient to render a person un- conscious. 4. Amount of CO in Exhaust Gases of Gasoline Motors. An analysis of exhaust gases from 101 cars and trucks tested by the U. S. Bureau of Mines (13) showed an average of 6.5 per •cent of carbon monoxide present in the gases exhausted. One •of the cars tested was exhausting 13.2 per cent of carbon losing 50 per cent of the gasoline. On the basis of this analysis, assuming that a car discharges one cubic foot of carbon monoxide per minute, the concentration, to a dangerous point, of carbon monoxide in a garage would be soon reached and easily determined. Professor Henderson of Yale University and his associates (12) have calculated that in .three minutes in a small garage of the simple type (10x10x20) the atmosphere apart from diffusion, would reach the dangerous concentration of fifteen parts in 10,000. 5 5. Selection of Method for Studying the Effects of CO in Persons Exposed to the Exhaust from Gasoline Motors. In order to determine the degree of CO health hazard involved, this study was planned by the Division of Industrial Hygiene. It was proposed in this first study to investigate the garage workers and their occupational environment. Among the physiological and chemical methods for the quanti- tative determination of carbon monoxide in the air was recom- mended that developed by Dr. Sayer and his associates of the U. S. Bureau of Mines (14). The method is based on this principal: the hemoglobin of a laked blood solution, exposed to> a mixture of air and carbon monoxide, after combining with either carbon monoxide or oxygen, will attain an equilibrium according to the respective partial pressures of the two gases. By determining the amount of hemoglobin combined with carbon monoxide through comparison with a color scale, and knowing the oxygen content of normal air and the value of the competi- tive pressure of 02 and CO for hemoglobin, an equation has been worked out which gives the content of carbon monoxide of an air CO mixture in parts of 10,000, being a "part" in 10,000, or 0.01 per cent, the unit adopted to express the various concen- trations of carbon monoxide in the air for purposes of ventilation. This method has proven to be very accurate with low per- centages of carbon monoxide, but on account of local working conditions it was abandoned for an approximate, but indeed simpler one, entirely answering the purposes of this study. The "Mine Safety Appliance Company," an industrial 'Pitts- burg, Pa. concern, manufacturers a Carbon Monoxide Detector (15) rapid, practical, extremely simple and sensitive enough to indicate approximately percentages of CO in the air below the immediate danger point, reading as low as 0.05 per cent, or five parts of carbon monoxide in 10,000 parts of air. The instrument is well spoken of by all who have used it. It is based on a colorimeter method and while it is doubtful whether concentrations of CO below 0.1 per cent can be definitely recorded by the instrument, its use in testing garage air was found depend- able for all practical purposes. For the quantitative determination of CO in the blood the Pyro-tannic acid method as described by Drs.. Sayers and Yant (i6) in 1922 and later developed and greatly simplified by the same authors and their associates (17) in 1923, was adopted. A compact and convenient field apparatus, marketed by the Mine Safety Appliance Co. of Pittsburg, Pa. was used. Both method and apparatus of a very simple technique have been entirely satisfactory and of great service in this study. This method is essentially colorimeter and based on the princi- ple that, if to laked human blood, the hemoglobin of which being in combination with carbon monoxide (COHb), is added a 1:1 solu- tion of tannic and pyro-gallic acids, a light carmine colored suspension is formed varying in shade according to the amount 6 of CO combined with the hemoglobin. Dr. Sayers and his associates have prepared from pigments a set of permanent color standards, made to match the color of blood solutions containing known percentages of carbon-monoxyhemoglobin. An unknown specimen of blood, treated with Pyro-tannic acids, is compared with this color scale and, if present, the amount of carbon monoxy- hemoglobin, is directly determined. The hemoglobin was determined by the Tallquist scale, 90 being considered as normal. 6. Procedure of Study. This study was begun in the first part of the month of Novem- ber, 1923. All through the month there was either no wind or, as a rule, only moderate winds, with prevailing cold weather, causing garage doors to be left hermetically closed. Lists of all garages by streets in the borough of Manhattan were prepared and the garages visited systematically beginning with those located in the lower east side, to which this study is limited. Over 157 garages, service stations and repair shops were visited including all types and sizes, as several large and modern garages were chosen at random in other parts of the city for comparative purposes, but those findings are not included in this study. A first failure must be reported here. All efforts and coaxing to induce garage workers, and chauffeurs when present, to submit themselves to part with a few drops of blood from the ear, in over 80 per cent of garages visited were unsuccessful. In 31 garages an average of only one or two persons per garage, w'ith a maximum of three chauffeurs in one garage, cooperated satis- factorily. Almost everybody seemingly was found to be interested in the subject of carbon monoxide poisoning, but after prolonged conversation, tending often to become jocular in character, the request of the inspector to submit to the simple test was dismissed with a finality not admitting any doubt. Altogether 42 men were tested. On account of these difficulties and of other causes involving a great loss of time, the ambitious aims of the investigation were curtailed and, therefore, this study cannot claim to be an exhaus- tive one, but only an index of "garaging conditions''. Two blank forms were prepared to record the findings, form A, for inspection of garages, and form B, for the examination of garage workers. Orginally, as the tests were planned, provision was made for two consecutive examinations, at different hours on the same day, of the garage air and of the garage workers' blood for compara- tive study, but in practice it was not possible, even once, to get any man to submit himself to a second test. The blood tests and the corresponding air tests were made on the same visit. 7 7. Tabulation of Findings. The most salient findings recorded in Forms A and B are given in tabular form in the following tables I and II. FORM "A" Date No Address Dimensions: x x = cu. ft. Number of floors Number of Doors Level with drive Closed Open Separate entrance and exits On same plane Opposite Number of Windows Closed Open Number of Skylights Closed Open Ventilators Functioning Exhausts Functioning INSPECTION OF GARAGES Lighting: Daylight Good Fair Poor Artificial Good Fair Poor Service: Repairs.... Service Station Storage Taxis High-priced cars Low-priced cars Trucks Types of Cars Movement of Cars From 6 A. M. to 12 Noon From 12 Noon to 6 P. M. From 6 P. M. to 6 A. M. Exhausts on Cars Number of Employees 1st Sample of Air CO content 2nd Sample of Air CO content Time of Day Time of Day Wind Wind Temperature Temperature Humidity c Humidity 8 EXAMINATION OF EMPLOYEES IN GARAGES FORM "B" Date No Address Name Age Length of employment Previous employment Length Skin conditions Pruritus Pallor Flushed.... Nausea.... Headache Frontal Occipital Temporal Photophobia Tremors Insomnia Narcotics Hours at Work: From to Mechanic Pusher Washer Chauffeur Heavy Physical Work First Test Time of day Pulse Respiration Hb. Polycythemia CO. Second Test Time of day Pulse Respiration Hb. Polycythemia CO. 9 TABLE I TABULATION OF DATA OF INSPECTION OF GARAGES AS RECORDED ON FORM "A" 1 2 3 4 5 6 7 8 9 10 Num- ber of garages Daily move- ment of cars Type o 1 cars Service given * Doors Win- dows Sky- lights Ven- tila- tion Per cent of CO in air Remarks 1 100 Trucks and touring.. Trucks and touring.. Touring St 2 Poor 0.20 Inspect. 8 a . m 2 3 20 15 RS. SS. St.. St. SS 1 2 " "4 ""i Poor Fair 0.05 0.05 4 5 6 100 10 5 Trucks and touring.. Touring and taxi.... Touring RS. SS. St.. SS. St St 3 1 2 ""2 1 Poor Poor Fair 0.15 0.05 7 50 Touring SS. St 2 Poor 0.10 8 12 Touring St 1 Poor 9 50 Touring SS. St 2 2 Fair 0.15 10 80 Touring St 3 6 1 Good 11 40 Touring St 2 Poor 12 13 25 10 Taxi and touring.... Touring SS. RS. St.. St 1 1 Poor Poor 0.10 Found adjust. 14 20 Touring SS. St 1 1 Poor 0.05 engine jof car 15 50 Touring RS. SS. St.. 2 Poor 0.10 16 17 15 70 Touring and taxi.... Touring SS. RS. St.. St 1 2 '"'4 ""2 Poor Good 0.15 18 25 Touring SS. St 1 Poor 0.15 19 20 50 100 Touring, taxi, truck.. Touring SS. RS. St.. SS. RS 2 2 ..... Poor Poor 0.15 0.10 21 22 30 60 Touring and trucks.. Touring SS. St St 3 2 2 4 ..... Fair Fair 0 05 0.05 23 24 30 15 Touring and taxi.... Touring SS. st SS. RS. St.. 1 1 Poor Poor 0.05 0.10 25 25 Touring SS. RS. St.. 2 Poor 0.15 26 150 25 Touring St 2 2 1 Good 27 Touring SS. St 1 Poor 0.15 28 40 Touring SS. St 1 Poor 0.15 29 15 Touring SS. st 2 1 Fair 0.10 30 20 Touring SS. RS. St.. 1 3 Fair 0.15 31 20 Touring SS. st 2 2 Fair 0.10 * St.= storage; SS.=service station; RS.=repair station. 10 NUMBER OF EMPLOYEE Age Length of employ- ment, years Kind of work Hours at work Head- aches Nervous manifes- tations Gastric symptoms Skin manifes- tations Pulse rate Per Cent of Remarks Hb CO Hb 1 2 3 4 5 6 7 8 9 10 11 12 13 1 50 7 M 2 F. Oc. T. + + O 82 85 18 z 20 4 M 3 F O + O 78 90 10 3 19 2 M 1 O O O O 76 90 0 4 30 12 M 4 F. Oc. + + P 90 80 30 Marked palor, temp. 99.4. 5 25 10 M 3 F o 0 P 79 80 18 6 32 12 M 1 O o o O 69 90 0 7 24 3 M 2 F o E 78 90 0 8 36 1 M 2 O o o O 68 90 0 9 36 15 M 4 F. Oc. T. + P 98 85 10 10 40 25 M 3 O o o O 64 90 0 11 25 5 C 1 T o 0 P 82 70 0 Insomnia narcotics 12 29 3 M 3 F + o P 96 90 10 13 20 6 M 2 F 0 + P 87 90 20 14 37 2 M 1 O o o P 79 90 18 Insomnia 15 48 15 M 2 F o + P 74 90 10 16 17 2 M 4 O 0 o P 96 85 15 17 23 4 C 2 O 0 0 O 78 90 10 18 31 7 M 3 F o + P 79 90 15 19 30 9 M 1 F o + O 80 85 18 Insomnia. 20 23 4 M 1 F o + 0 87 90 10 21 22 1 M 4 F o + F 81 90 20 22 22 1 C 3 O o o O 75 90 0 23 29 2 C 3 F 0 o o 70 90 10 24 21 2 C 0 O o 0 0 81 90 0 25 18 1 M 1 O o o p 89 90 15 26 28 3 M 1 O o o p 74 90 0 27. 47 19 M 3 F 0 p 73 90 10 Insomnia. 28 32 4 M 3 O o 0 p 81 90 10 29 27 6 C 1 O o o o 68 80 0 30 41 7 M 3 F o + p 73 90 10 Insomnia. 31 39 2 M 1 O o o o 85 0 32 32 5 C 4 O o o o 67 90 0 TABLE II TABULATION OF DATA OF EXAMINATION OF EMPLOYEES OF GARAGES AS RECORDED ON FORM " B " 11 33 29 27 5 6 M M 3 2 O o 0 o 0 0 p 87 79 90 90 15 10 34 35 47 25 M 3 O o o o 74 80 10 36 39 17 M 3 o o o p 81 90 15 37 24 2 M 2 F + + p 87 90 10 38 29 2 M F + + p 94 90 20 39 23 1 M 4 F. Oc. + + p 83 85 20 40 31 15 M 2 O o o o 79 90 10 41 21 4 M 1 o o () p 70 80 10 42 18 4 M 1 o o o p 65 85 0 Narcotics. 12 8. Analysis of Data. An analysis of Table II shows that 69.5 per cent of the workers examined reacted positively. Not all of the men examined where the CO concentration in the air was demonstrable, shows a corresponding percentage of COHb or gave a positive test at all; conversely in some shops where it was not possible to demonstrate any CO in the air, some men gave a positive test for COHb. These apparent discrepancies are easily explained first, by knowing that, if only a moderate amount of CO has been absorbed it may be thrown off in a few hours, the rate of the elimination being 30 per cent to 50 per cent per hour (12) depending on the amount of fresh air breathed and secondly, a mechanic testing and adjusting a gasoline motor for one hour may have absorbed enough CO to show a COHb saturation of 22 per cent, when the concentration of CO in the air of the workshop or room may not have reached four parts in 10,000 (12). A test of the air surrounding a gasoline motor in a large room with the engine running, taken at ten feet from the exhaust and at a height of four feet from the floor, contained ten parts of carbon monoxide in 10,000 (0.1%) while in other parts of the room at 30 feet from the motor it was not possible to obtain a positive test. Headaches were common in almost all cases, and gastric symp- toms were present in many, although not all the men examined were willing to admit any discomfort, deriving from their occu- pation. Pallor of the skin was general in a more or less degree. The pulse rate was not very noticeably altered by the CO content in blood, but even within wide normal limits of variation, a tendency was shown toward an increase of rate. Another unexpected finding was the amount of hemoglobin present. The pallor of the face, in some cases (Table II, No. 3) almost of waxy hue, but generally sallow, recalled blood diseases due to absolute or relative reduction of hemoglobin, but in all cases, excepting one (Table II, No. 11) in which the marked pallor might have been due to the use of narcotics, the hemoglobin was normal or near to normal. Unfortunately a routine micro- scopical examination of the blood was not possible, but in case No. 3, Table II, the blood findings were: red count 4,500,000, and the stained specimen showed only a few macrocytes present, otherwise normal. Explanations can be offered to account for the amount of hemoglobin present: a compensatory polycythemia (6) or perhaps, if I may venture to express an opinion, the alteration of the color of the skin may be dependent upon dis- turbances of the subcutaneous circulation of nervous origin. Admitting that the values for COHb in Table II were but approximate, and that the workers who volunteered to be examined were only those who felt themselves to be in a certain state of invalidism, the importance of the test lies in the demonstration TABLE III RELATION BETWEEN CO AIR AND COHB-NUMBER OF EMPLOYEES AND OF CORRESPONDING GARAGES 0.5 0 0.25 0.20 0.15 0.10 0.05 0.00 /-ter of f&/76 1. Z. 5. 4-. 5. 6. 7. & 7. 10.11.12.13. 11. 15. U. 17. 1& 17. ZQ.Z1.ZLZIZH5.ZL A/ 3. /~u// L /ne C OH/b per cen/n/^es. StentedPortion sriowo-por continyos of CQ/n/l/f 13 of the existence of a health hazard in any occupation where the worker is exposed to exhaust gas. Table II is very instructive. In 77.5 per cent of the garages inspected carbon monoxide was present in the air in different con- centrations. Not one of the garages inspected had any artificial system of ventilation. Ventilation was inadequate in all garages inspected, even in the few abounding with skylights and windows, which were all kept hermetically closed on account of the seasonal temperature. In the few garages for which the ventilation was recorded as "good" (Table I, Nos. 10, 17, 26) the casual factor was probably the strong wind blowing on the day on which the inspection was made, the velocity of the wind on that day being recorded as 33 by the U. S. Weather Bureau at its Park Station. The difference in CO content found in the air of the garages inspected can be accounted for, in part, by the different kinds of fuel and by the "rich" or "lean" mixtures of gasoline used, but in the garages where repairs and adjustment of the engines were made, the air conditions, as regards the CO content, were systematically bad. (Table I, Nos. 7, 15, 16, 19, 20, 24, 25, 30.) In the old garages which are all readaptations of livery stables or barns, or old buildings, the danger is patent, it being im- material whether they are used for storage or for other auto- mobile purposes. An instance is the storage garage No. 1, Table I, an old livery stable, of large dimeansions, beneath a dwelling house, dark and damp and irregular in construction, in which at about 8 A. M. the CO content of the air, in one of the many corners, reached 0.20 per cent and the proprietor, who "had not been feeling quite well for a long time" reacted positively as high as COHb 18 per cent saturation. This particular garage had been storing heavy trucks for the night and it was almost empty at the time of the inspection, but carbon monoxide (CO) although lighter than air rises slowly and does not oxidize to carbon dioxide (CO2) spontaneously. In Table III is represented in graphic form the relation between COHb in employees of garages and CO air in corresponding garages. 9. Recommendations. The remedies for the above conditions come under two head- ings: (a) The application of the State Laws, (b) the general adoption of the ingenious suggestion of Drs. Henderson and Haggard of Yale University (18) of the vertical exhaust for the automobile. Exhaust gases from gasoline engines if discharged vertically wTould continue to rise on account of their initial linear velocity and on account of their temperature, higher than the surrounding 14 air. Any opening in the ceiling of the garage or shop would allow the carbon monoxide and other gases to escape before mixing very much comparatively speaking with the air of the shop. Carbon monoxide poisoning unfortunately is not contemplated by the New York State Workmen's Compensation Law as an occupational disease, but although the legislators under Article I, Section 3, Par. 1 by the word "injuries" probably had in mind only traumatic injuries of the most obvious tissues of the body, nevertheless carbon monoxide causes an injury to one of the most important tissues of the body, the blood, a functional injury which would ultimately lead to somatic death by the abeyance of its vital functions as a carrier of oxygen, and therefore may enter within the spirit of the law. 10. Conclusions. Although cases applying for compensation for chronic CO poisoning are not on record so far, it is already recognized by general practitioners and the public that exposure to even small percentages of CO is a factor detrimental to health and causing loss of time to employees exposed to the exhaust from gasoline motors. In Table II, No. 4, of this study, a case was found in which carbon monoxide chronic poisoning was markedly outstanding and plainly calling for compensation. A fair attitude toward labor therefore would be to make chronic carbon monoxide poisoning a compensable disease in the State of New York. 1. National Automobile Chamber of Commerce - ''Facts and Figures of the Automobile Industry", 1923. 2. Chilton Automobile Trade List, March 1923. 3. Fourteenth Census of the United States. Population. 4. "Occupation Hazards and Diagnostic Signs". By Dr. Louis I. Dublin, U. S. Dept, of Labor, Bureau of Labor Statistics, Bulletin No. 306, April, 1922. 5. "The Regulation of the Lung Ventilation". I. S. Haldane and I. G. Priestly. Journal of Physiology, 1905, XXXII. 6. Preventive Medicine & Hygiene. Prof. Milton J. Rosenau, 1916. 7. ' ' The Iodometric Determination of ' Small Quantities of Carbon Monoxide". Leonard P. Kinnicut and George R. Sanford. Journal Am. Chern. Society, 1900, XXII. 8. "Methods of Air Analysis". John S. Haldane, 1920. 9. Modern Gas Work Practice. A. Mead, 1921. 10. Haldane, J. S. Respiration. Yale Univ. Press. 1922. 11. "The Treatment of Carbon Monoxide Poisoning", Howard W. Haggard and Yandell Henderson. Jour, of The Am. Med. Ass'n. Oct. 1, 1921, LXXVII. 12. "Physiological Effects of Automobile Exhaust Gas and Standard of Ventilation, etc.' Yandell Henderson, Howard REFERENCES. 15 W. Haggard, M. C. Teague, A. L. Prince, R. M. Wunder- lich. Jour, of Industrial Hygiene. Aug. 1921, Vol. Ill, No. 3, 4. 13. "The Sampling and Analysis of Automobile Exhaust Gas". A. C. Fieldner and G. W. Jones. Reprint from the Journal of the Franklin Institute, Nov. 1922. 14. "The Pyro-tannic Acid Method for the Quantitative Deter- mination of Carbon Monoxide in blood and Air". R. R. Sayers, W. P. Yant and G. W. Jones, Dept, of the Interior - U. S. Bureau of Mines - Reports of Investigations, Serial No. 2486, June 1923. 15. The "M-S-A Carbon Monoxide Detector". Mine Safety Appliance Co., Pittsburg, Pa. Bulletin No. 60. 16. The Tannic Acid Method for Quantitative Determination of Carbon Monoxide in the Blood". R. R. Sayers, and W. P. Yant. Reprint No. 790 from the U. S. Public Health Service Reports, Oct. 6, 1922. 17. "Pyro-Tannic Acid Method for CO Determination". By R. R. Sayers, W. P. Yant and G. W. Jones. U. S. Public Health Service. Reports Vol. 38, No. 40. 18. "Health Hazard from Automobile Exhaust Gas in City Streets, Garages and Repair Shops." By Prof. Yandell Henderson and Dr. Howard W. Haggard. Journal of the Am. M,ed. Ass'n, Aug. 4, 1923, Vol. 81. 19. "New York State Labor Law" with amendments, additions and annotations to Aug. 1, 1923. Issued under the direc- tion of Bernard L. Shientag, Industrial Commissioner. 20. New York State Workmen's Compensation Law with amend- ments, additions and annotations to Aug. 1, 1923. Issued under the direction of Bernard L. Shientag, Industrial Commissioner.