AMERICAN ELECTRO-THERAPEUTIC ASSOCIATION. OFFICE OF THE SECRETARY, 68 MADISON AVENUE, NEW YORK. At a meeting of the Executive Council of the American Electro- Therapeutic Association, held at the office of the Secretary, March 2d, 1893, the following resolution was adopted : “ Resolved., That the Secretary be instructed to prepare a circular to send to Fellows of the Association, to members of the medical pro- fession, to electrical experts and to manufacturers of electrcial ap- pliances for medical work, containing titles of all the committees, the members serving on them with their addresses and the matter prepared for discussion and investigation by each committee. “And that manufacturers be asked to communicate with the mem- bers of the different committees, if they desire to have their instru- ments examined and tested, stating their claims and merits. “ And that physicians, electrical experts and manufacturers be asked to co-operate in making suggestions and in relating their exper- ience and preference for instruments, with reason and data. “And to mail this circular to all members of the Association, man- ufacturers, medical journals and to others who are known to use electricity extensively, asking for a speedy reply either to the Secre- tary or to the members of the respective committee whom it concerns.” In accordance with the above resolution the following has been prepared : 2 COMMITTEE ON STANDARD COILS. Dr. W. J. Morton, 19 East 28th St., New York. Dr. A. H. Goelet, 351 West 57th St., New York. Dr. Wm. F. Hutchinson, Providence, R. I. Dr. G. J. Engelman, 3003 Locust St., St. Louis Mo. ♦ Mr. A. E. Kennelly, Chief Electrician, Edison Laboratory, Orange, .New Jersey. POINTS TO BE CONSIDERED. I. Portability. 11. Practical mechanism of machines as adapted to physicians’ use. 111. Range and rate of vibration. IV. Electro-motive force and its range in relation to resistances to be overcome. V. The resistance of the coil producing these electro-motive forces VI. The battery-power required for individual coils. VII. Shape of the generated wave of electro motive force. COMMITTEE ON STANDARD METERS. Dr Margaret A. Cleaves, 68 Madison Ave., New York. Dr. Emil Heuel, 352 Willis Ave., New York. Mr. W. J. Jenks, Electrical Engineer, 44 Broad St, New York. POINTS TO BE CONSIDERED. I. A good meter should have a clear, legible scale, fairly uniform over the range, and not crowded at different points. 11. It should be capable of being noted or observed at a distance. 111. The resistance should be low. IV. There should be no tendency to overheat with the strongest current employed. V. It would be advantageous to avoid a shunt, if one milliampere can be read throughout the scale. YI. The instrument should be capable of indicating in all positions. VII. Any instrument whose indications depend directly upon the local magnetic force is objectionable, for the reason that 3 its indications are liable to be affected by iron in the vicinity, VIII. The suspended system should require as little attention as possible, either for adjustment or shipment. IX. It is an advantage for the instrument to indicate with either direction of the current. X. Portability. XI. Liability to fracture. COMMITTEE ON STANDARD ELECTROSTATIC OR INFLUENCE MACHINES. Dr. W. J. Morton, 19 East 28th St., New York. Dr. J. H. Kellogg, Battle Creek, Mich. Dr. G. Betton Massey, 212 South 15th St., Philadelphia. Dr. Margaret A. Cleaves, 68 Madison Ave., New York. POINTS TO BE CONSIDERED. I. Electro static machine best adapted to medical work, to be determined by its “output.” Its output to be determined as follows: (a) At, respectively, 100 and at 150 revolutions per minute. (£) With two Leyden jars, each of whose outer metallic surfaces has the area of x ix\ inches = square inches. (0 With discharging-rods having ball terminals one inch in diameter and arranged respectively six inches and ten inches apart. (d) Give the number of sparks per minute which will pass between the discharging-rods. 11. Give the greatest maximum length of spark with machine arranged as in Section 1., except as to distance apart of the discharging-rods. 111. Give the maximum length of the brush discharge between the discharging-rods with machine arranged as in Section 1., except that no Leyden jars are used. 4 IV. Give the maximum length of spark that may be obtained by a brass-ball electrode two inches in diameter, from a person’s back, seated in the usual manner upon an insulated plat form—the platform connected to one prime conductor of the machine, the other being connected to the ground. (a) With above Leyden jars. (b) Without Leyden jars. Y. Kind of electro-static machine best adapted to medical work, whether a Holtz, Wimshurst, Toepler, Voss, Carre, Lewan- dowski, Toepler-Holtz, Wimshurst-Holtz or machine not here named, provided the type as constructed successfully fulfills requirements outlined in Section I. VI. Does the machine preferred easily reverse its charge ? Does it maintain its charge successfully ? VII. Facility and means of charging machine under all atmospheric conditions. VIII. Can a good meter to measure the output of the machine be suggested ? IX. Mechanical construction of machine. (a) Ease of actuating machine by motive power. (b) Durability of the mechanism causing the revolution of its plates. (