<?xml version="1.0" encoding="UTF-8"?>
<tt xml:lang="en" xmlns="http://www.w3.org/2006/04/ttaf1"  xmlns:tts="http://www.w3.org/2006/04/ttaf1#styling">
	<head>
		<styling>
			<style id="1" tts:backgroundColor="black"  tts:fontFamily="Arial" tts:fontSize="14" tts:color="white" tts:textAlign="center" tts:fontStyle="Plain" />
		</styling>
	</head>
	<body>
	<div xml:lang="en" style="default">
			<p begin="00:00:00.033" end="00:00:05,713" style="1">[silence]</p>
			<p begin="00:00:24.285" end="00:00:26,989" style="1">This leader permits the projectionist</p>
			<p begin="00:00:27.069" end="00:00:30,852" style="1">to adjust focus and soundfor the picture that follows</p>
			<p begin="00:00:51.217" end="00:00:56,259" style="1">the insertion and removalof the intrauterine device or IUD.</p>
			<p begin="00:01:04.820" end="00:01:07,700" style="1">This IUD is the Lippes loop.</p>
			<p begin="00:01:09.180" end="00:01:12,480" style="1">It is a small, flexible plastic device.</p>
			<p begin="00:01:14.940" end="00:01:20,040" style="1">It rests in the uterine cavity and ishighly effective in preventing pregnancy.</p>
			<p begin="00:01:22.200" end="00:01:25,300" style="1">The Lippes loop is designedto be straightened out</p>
			<p begin="00:01:25.380" end="00:01:27,960" style="1">and inserted through a plastic tube.</p>
			<p begin="00:01:48.240" end="00:01:52,900" style="1">As shown on this model,the tube called the inserter</p>
			<p begin="00:01:52.980" end="00:01:58,860" style="1">is slipped into the cervical canaland the device is pushed into the uterus.</p>
			<p begin="00:02:00.120" end="00:02:06,340" style="1">Once inside the uterine cavity,the IUD recoils to its original shape</p>
			<p begin="00:02:06.420" end="00:02:09,360" style="1">and may remain in place for many years.</p>
			<p begin="00:02:17.640" end="00:02:23,340" style="1">The threads enable the patientto determine that the IUD is in place.</p>
			<p begin="00:02:24.180" end="00:02:26,760" style="1">They also permit easy removal.</p>
			<p begin="00:02:29.400" end="00:02:33,040" style="1">The IUD differsfrom all other methods of contraception</p>
			<p begin="00:02:33.120" end="00:02:38,040" style="1">in that, once inserted,it requires little further attention.</p>
			<p begin="00:02:42.360" end="00:02:46,540" style="1">As shown in these drawings,the technique of insertion depends</p>
			<p begin="00:02:46.620" end="00:02:48,880" style="1">on the doctor&apos;s abilityto locate accurately</p>
			<p begin="00:02:48.960" end="00:02:54,660" style="1">the position of the uterus,the anterior position, the mid position,</p>
			<p begin="00:02:58.920" end="00:03:00,540" style="1">the posterior position,</p>
			<p begin="00:03:03.780" end="00:03:08,940" style="1">and to place the IUDin the frontal plane of the uterine cavity.</p>
			<p begin="00:03:15.240" end="00:03:21,340" style="1">The instruments needed for insertionare the speculum, the sponge forceps,</p>
			<p begin="00:03:21.420" end="00:03:25,740" style="1">the inserter, the plunger, and the IUD.</p>
			<p begin="00:03:27.660" end="00:03:30,300" style="1">The metal instruments are sterilized.</p>
			<p begin="00:03:33.840" end="00:03:39,480" style="1">Since the plastics cannot be boiled,they are sterilized in iodine solution.</p>
			<p begin="00:03:40.680" end="00:03:43,920" style="1">Preparation of the solution is as follows.</p>
			<p begin="00:03:47.580" end="00:03:48,833" style="1">To tap water,</p>
			<p begin="00:03:55.200" end="00:03:59,340" style="1">tincture of iodineis added until an orange color is obtained.</p>
			<p begin="00:04:03.420" end="00:04:05,940" style="1">Yellow is not strong enough.</p>
			<p begin="00:04:18.600" end="00:04:21,340" style="1">The plastic equipment should be immersed</p>
			<p begin="00:04:21.420" end="00:04:26,040" style="1">in the orange iodine solutionfor five minutes before using.</p>
			<p begin="00:04:30.660" end="00:04:33,960" style="1">The sterile tray is set up for the patient.</p>
			<p begin="00:04:39.780" end="00:04:43,980" style="1">The clinical procedurebegins with the insertion of the speculum.</p>
			<p begin="00:05:04.860" end="00:05:08,020" style="1">Then the physician takesa Papanicolaou smear</p>
			<p begin="00:05:08.100" end="00:05:11,280" style="1">if none was obtained during the last year.</p>
			<p begin="00:05:31.020" end="00:05:36,000" style="1">Next, he performs a bimanual examinationto detect any abnormalities</p>
			<p begin="00:05:36.720" end="00:05:38,520" style="1">and to note the uterine position.</p>
			<p begin="00:05:49.260" end="00:05:54,840" style="1">With the routine examination completed,the speculum is reinserted.</p>
			<p begin="00:05:58.920" end="00:06:01,500" style="1">The cervix is swabbed with cotton.</p>
			<p begin="00:06:06.480" end="00:06:10,380" style="1">Sterile gloves are put onbefore handling the Lippes loop.</p>
			<p begin="00:06:29.100" end="00:06:33,120" style="1">Because the plasticdevices have a limited ability to recoil,</p>
			<p begin="00:06:33.720" end="00:06:39,060" style="1">the IUD is placed in the inserterimmediately before the actual insertion.</p>
			<p begin="00:06:55.200" end="00:06:59,140" style="1">The IUD should be loadedso that when the black indicator</p>
			<p begin="00:06:59.220" end="00:07:04,140" style="1">is horizontal at the cervical os,the IUD will extrude in the frontal plane.</p>
			<p begin="00:07:12.300" end="00:07:16,120" style="1">The inserter is slipped gentlyinto the cervical canal past</p>
			<p begin="00:07:16.200" end="00:07:17,653" style="1">the internal os</p>
			<p begin="00:07:22.020" end="00:07:24,661" style="1">and the IUD is inserted.</p>
			<p begin="00:07:35.340" end="00:07:38,380" style="1">The plunger is removed first</p>
			<p begin="00:07:38.460" end="00:07:43,440" style="1">so that the strings will not be caughtand the device accidentally pulled out.</p>
			<p begin="00:07:46.680" end="00:07:47,740" style="1">On some patients,</p>
			<p begin="00:07:47.820" end="00:07:52,920" style="1">abdominal pressure will simplify insertionby straightening an anterior uterus.</p>
			<p begin="00:07:55.980" end="00:08:00,300" style="1">Press, hold, push in.</p>
			<p begin="00:08:10.800" end="00:08:15,000" style="1">Occasionally, the uterus may needto be straightened with a tenaculum.</p>
			<p begin="00:08:23.220" end="00:08:28,020" style="1">A uterine sound will helpto confirm the position of the uterus.</p>
			<p begin="00:08:42.660" end="00:08:46,440" style="1">The inserter passes easilyinto the straightened uterus</p>
			<p begin="00:08:49.620" end="00:08:52,140" style="1">and the IUD  is inserted.</p>
			<p begin="00:08:53.100" end="00:08:55,540" style="1">A fluoroscopic view of the pelvis shows</p>
			<p begin="00:08:55.620" end="00:08:59,940" style="1">the speculum with a Lippes loop enteringthe frontal plane of the uterine cavity.</p>
			<p begin="00:09:11.340" end="00:09:15,120" style="1">In the normal procedure,after the routine examination,</p>
			<p begin="00:09:15.840" end="00:09:17,820" style="1">the speculum is reinserted.</p>
			<p begin="00:09:33.120" end="00:09:35,160" style="1">The cervix is swabbed with cotton.</p>
			<p begin="00:09:48.120" end="00:09:51,300" style="1">The inserter is pushed in gentlyto the black rubber mark</p>
			<p begin="00:09:53.040" end="00:09:55,200" style="1">and the IUD is inserted.</p>
			<p begin="00:09:55.800" end="00:10:01,080" style="1">The ID may cause increased menstrual flowduring the third three months.</p>
			<p begin="00:10:14.940" end="00:10:18,600" style="1">The plungerand then the inserter are removed.</p>
			<p begin="00:10:27.960" end="00:10:31,200" style="1">The strings should be in placeat the cervical os.</p>
			<p begin="00:10:33.900" end="00:10:37,860" style="1">The IUD can be removed easilyby pulling the strings.</p>
			<p begin="00:10:53.200" end="00:10:54,513" style="1">In brief review,</p>
			<p begin="00:10:55.080" end="00:10:58,260" style="1">if the physician notes accuratelythe position of the uterus,</p>
			<p begin="00:11:01.200" end="00:11:05,880" style="1">if he places the IUD so that it will enterthe frontal plane of the uterine cavity,</p>
			<p begin="00:11:09.480" end="00:11:12,660" style="1">insertion  is performed without difficulty.</p>
		</div>
	</body>
</tt>
